Versiv Cabling Certification Product Family
Users Manual
128
Step 1: Set the Reference in Loopback Mode
1-1
Turn on the tester and let it sit for a minimum of 5 minutes.
Let it sit longer if it is above or below ambient temperature.
1-2
Make sure that the home screen shows the correct settings for
the job, and the test type is
Loopback
.
To make sure that other settings are correct, tap the test
setup panel, make sure the correct test is selected on the
CHANGE TEST
screen, then tap
EDIT
to see more settings.
Table 6 on page 111 describes the settings.
1-3
Clean and inspect the connectors on the tester and test
reference cords.
1-4
On the home screen tap
SET REF
.
1-5
On the
SET REFERENCE
screen, tap
RUN WIZARD
.
Notes
To only set the reference, and not measure the
loss of your test reference cord, tap SKIP WIZARD
on the SET REFERENCE screen.
Fluke Networks recommends that you measure
the loss of your test reference cord each time you
set the reference.
1-6
Make the connection to set the reference, as shown on the
screen, then tap
NEXT
to see the completed connections.
Figure 50 also shows the completed connections.
Notes
The SET REFERENCE screen shows reference
connections for the selected reference method.
Figure 50 shows connections for the 1 Jumper
reference.
When you set the reference, keep the fiber as
straight as possible.
-continued-
Summary of Contents for Versiv
Page 38: ...Versiv Cabling Certification Product Family Users Manual 24...
Page 86: ...Versiv Cabling Certification Product Family Users Manual 72...
Page 202: ...Versiv Cabling Certification Product Family Users Manual 188...
Page 214: ...Versiv Cabling Certification Product Family Users Manual 200...
Page 234: ...Versiv Cabling Certification Product Family Users Manual 220...
Page 244: ...Versiv Cabling Certification Product Family Users Manual 230...
Page 256: ...Versiv Cabling Certification Product Family Users Manual 242...
Page 258: ...Versiv Cabling Certification Product Family Users Manual 244...