Fluke U1500s Instructions Manual Download Page 1

PN 

5161539

 June 2019

©2019 Fluke Corporation. 
All rights reserved. Specifications are subject to change without notification. 
All product names are trademarks of their respective companies.

U1500s

High Voltage Differential Probe

Instructions

Introduction

The Fluke U1500s High Voltage Differential Probe (the Probe or 
Product) is a portable voltage sensor with a 1500 V dc/1000 V ac range 
and 0.1 % accuracy. 

How to Contact Fluke

To contact Fluke, call one of the following telephone numbers:

Technical Support USA: 1-800-44-FLUKE (1-800-443-5853)

Calibration/Repair USA: 1-888-99-FLUKE (1-888-993-5853)

Canada: 1-800-36-FLUKE (1-800-363-5853)

Europe: +31 402-675-200

Japan: +81-3-6714-3114

Singapore: +65-6799-5566

Anywhere in the world: +1-425-446-5500

Customer Service Center (Fluke China): + 400-810-3435

Maintenance Service Center (Fluke China): +400-921-0835

To view, print, or download the latest manual supplement, visit 

http://us.fluke.com/usen/support/manuals

.

Go t

www.fluke.com

 to register your product and find more information.

Safety

Warning

 identifies conditions and procedures that are dangerous to 

the user.

XW

 Warning

To prevent personal injury and for safe operation of the 
Product:
• Read all safety information before you use the Product.
• Use the Product only as specified, or the protection

supplied by the Product can be compromised.

• Comply with local and national safety codes. Use

personal protective equipment (approved rubber gloves,

face protection, and flame-resistant clothes) to prevent

shock and arc blast injury where hazardous live

conductors are exposed.

Summary of Contents for U1500s

Page 1: ...ngapore 65 6799 5566 Anywhere in the world 1 425 446 5500 Customer Service Center Fluke China 400 810 3435 Maintenance Service Center Fluke China 400 921 0835 To view print or download the latest manu...

Page 2: ...the battery door is opened Do not work alone Do not exceed the Measurement Category CAT rating of the lowest rated individual component of a Product probe or accessory Do not touch voltages 30 V ac rm...

Page 3: ...off the Product after test completion then unplug the test leads Conforms to relevant Australian Safety and EMC standards Conforms to relevant South Korean EMC Standards Measurement Category III is ap...

Page 4: ...Disconnect all Probe connections 2 Make sure that the power switch is OFF 3 Use a flat blade screwdriver to rotate the battery door fastener to the unlocked position 4 Remove the battery door 5 Insta...

Page 5: ...Have an approved technician repair the Product If the Product does not perform properly use these steps to help isolate the problem 1 Verify that battery capacity meets the requirements 2 Verify that...

Page 6: ...V DC 1500 V Electromagnetic Compatibility EMC International IEC 61326 1 Portable Electromagnetic Environment IEC 61326 2 2 CISPR 11 Group 1 Class A Group 1 Equipment has intentionally generated and or...

Page 7: ...R 15 subpart B This product is considered an exempt device per clause 15 103 Electrical Specifications Measurement Range 1000 V ac rms 1500 V dc Accuracy 0 1 of reading 0 1 of Range Bandwidth 100 kHz...

Page 8: ...on then send the product to that Service Center with a description of the problem THIS WARRANTY IS YOUR ONLY REMEDY NO OTHER WARRANTIES SUCH AS FITNESS FOR A PARTICULAR PURPOSE ARE EXPRESSED OR IMPLIE...