Operation of the device, sensor system and apps
SONOCHEK
45
SONOCHEK 09.2018
3.5
Description and operation of the structure-borne sound sensor and
temperature sensor DBS20
3.5.1
Safety instructions
Risk of injury!
The peak ends of the probe tips may cause injuries. The long probe tip
can even cause severe injuries. Ensure that no one is injured with the tip
end of the probe tips. Never point the tip at other people.
Carrying the sensor on the body can cause severe injuries. Always carry
the structure-borne sound sensor with attached probe tips with the tips
pointed away from the body in order to avoid injuries.
Your hands may be crushed by the high magnetic attractive force of the
magnetic adapter. Obliquely place the magnetic adapter on the
measured object as slowly as possible.
Important!
It is not permitted by the IATA to transport the DBS20-5 in hand luggage.
3.5.2
Applications and intended use
The structure-borne sound sensor with changeable attachments is used, among other things,
for the following:
State monitoring of machines and systems
Functional check of condensate drains and valves
Monitoring of wear and malfunctions in bearings
Monitoring of lubrication states
Sensor attachment
Application
Conditions
To be observed
Magnetic adapter
Bearings
The existing coupling
surface should be flat and
magnetic. A screw
connection in the housing
is ideal.
Some assembly pad
adhesives may have a
dampening effect.