123B/124B/125B
Users Manual
hxv11.eps
Figure 10. AutoReading Function
Measurement Type
To manually set up or change the measurement type:
1.
Push
to open the Scope and Meter button bar.
2.
Push
1
to open the MEASURE menu for Input A.
Push
4
to open the MEASURE menu for Input B.
3.
Push
Z
/
Y
to highlight the measurement type, for
example,
Hz
.
When more setup selections are available for a
measurement type, you see a
. Push
to open
the submenu and make a selection.
hxv12.eps
4.
Push
to accept the measurement type and
close the menu.
5.
Confirm that the selected measurement type is the
main reading. The former main reading moves to the
smaller secondary reading position.