C-1
Appendix C
Common Causes of Fiber Link Failures
Most problems in fiber links are caused by dirty,
scratched, or damaged connectors, as shown in
Table C-1.
The table shows results of a survey of 89 contractors and
private network owners. The results show what
percentage of each group reported finding the faults
listed.
Table C-1. Fiber Failure Survey Results
Fault Network
Owners
Contractors
Dirty end-faces
80 %
98 %
Poor polishing
72 %
88 %
Broken connectors
40 %
86 %
Mislabeling
8 %
86 %
Shattered end-faces
34 %
82 %
Bad splices
36 %
74 %
Excessive bends
6 %
66 %