OF-500 OptiFiber Certifying OTDR
Technical Reference Handbook
6-10
Table 6-1. Loss/Length Test Settings (cont.)
Location Setting
Description
CONNECTOR TYPE
Select the type of connector used in the cabling. This setting affects the
diagrams shown for reference connections. If the cabling's connector type
is not listed, use
General
.
Loss/Length
Tab
NUMBER OF
ADAPTERS
NUMBER OF
SPLICES
If the selected limit uses a calculated loss limit, enter the number of
adapters and splices that will be added to the fiber path after the reference
is set. Figure 6-3 shows an example of how to determine the
NUMBER OF
ADAPTERS
setting.
Loss/length test limits that include maximum values for the loss per km, loss
per connector, and loss per splice use a calculated limit for overall loss. Only
limits with all three values use a calculated loss limit. For example, fiber
backbone limits use a calculated loss limit. The
OVERALL LOSS
value should
be
N/A
in these limits. If a loss value is entered, it is ignored.
These settings do not apply to Far End Source mode because the loss per
km calculation requires a length measurement, and length is not measured
in Far End Source mode.
To see the limit’s values, select
TEST LIMIT
on the
Loss/Length
tab; then
press
A
View Limit
.
-continued-
Summary of Contents for OF-500 OptiFiber
Page 12: ...OF 500 OptiFiber Technical Reference Handbook x ...
Page 18: ...OF 500 OptiFiber Technical Reference Handbook xvi ...
Page 27: ...Getting Acquainted Powering the Tester 1 1 9 ajt20f eps Figure 1 1 Battery Pack Features ...
Page 29: ...Getting Acquainted Verifying Operation 1 1 11 ajt56f eps Figure 1 2 Removing the Module ...
Page 46: ...OF 500 OptiFiber Certifying OTDR Technical Reference Handbook 1 28 ...
Page 136: ...OF 500 OptiFiber Certifying OTDR Technical Reference Handbook 4 6 ...
Page 192: ...OF 500 OptiFiber Certifying OTDR Technical Reference Handbook 6 48 ...
Page 254: ...OF 500 OptiFiber Certifying OTDR Technical Reference Handbook 11 36 ...
Page 256: ...OF 500 OptiFiber Certifying OTDR Technical Reference Handbook ...
Page 272: ...B 14 OF 500 OptiFiber Certifying OTDR Technical Reference Handbook ...
Page 274: ...OF 500 OptiFiber Certifying OTDR Technical Reference Handbook C 2 ...
Page 282: ...OF 500 OptiFiber Technical Reference Handbook 8 ...