background image

 

IT100 

IntelliTone

 Toner and Probe 

 

 

 

Users Manual 

  

 

 

October 2003  Rev. 1 6/05 

© 2003, 2005 Fluke Corporation. All rights reserved.  
All product names are trademarks of their respective companies. 

Summary of Contents for IT100 IntelliTone Toner

Page 1: ...IT100 IntelliTone Toner and Probe Users Manual October 2003 Rev 1 6 05 2003 2005 Fluke Corporation All rights reserved All product names are trademarks of their respective companies...

Page 2: ...r or replace ment of a defective product which is returned to a Fluke Networks authorized service center within the warranty period To obtain warranty service contact your nearest Fluke Networks autho...

Page 3: ...one Toner 3 IT100 IntelliTone Probe 3 Safety Information 4 Battery Status 5 Auto Power Down 5 Locating and Isolating Cables with the IntelliTone Function 5 ValidatingTelephone Service and Polarity 8 T...

Page 4: ...es 12 Specifications 13 Environmental and Regulatory Specifications 13 IT100 Toner Electrical and Functional Specifications 14 IT100 Probe Electrical and Functional Specifications 14 Feature Compatibi...

Page 5: ...iii List of Figures Figure Title Page 1 Locating and Isolating Cables 7 2 Validating Telephone Service and Polarity 8 3 Continuity Test 9 4 Powering a Telephone Test Set 10 5 Replacing the Battery 12...

Page 6: ...IT100 Users Manual iv...

Page 7: ...you validate voice service The toner and probe feature IntelliTone toning and detection The digital IntelliTone signal is easier to detect in many environments than analog tones and its frequency and...

Page 8: ...uct Fill out the form then mail or fax it to the appropriate address for your country Contacting Fluke Networks www flukenetworks com support flukenetworks com 1 425 446 4519 Australia 61 2 8850 3333...

Page 9: ...45 to RJ45 patch cord Test lead set banana jacks to alligator clips F connector adapter female to female Quick Reference Guide Product Manuals CD IT100 IntelliTone Toner IT100 Toner with 9 V battery 1...

Page 10: ...use the toner probe or test leads if they are damaged Inspect the cases and test leads for damage before use Disconnect unused test leads and connectors from the toner when testing telephone circuits...

Page 11: ...11 for more information on the battery Auto Power Down The toner turns off automatically after 4 hours of inactivity The probe turns off automatically after 1 hour of inactivity To reactivate the tone...

Page 12: ...obe s LEDs light up from 1 to 8 as the signal strength increases The higher the number the stronger the signal Note If you cannot locate the IntelliTone signal on 2 conductor cables the cable may be s...

Page 13: ...10 0 PR OB E I NTELL I T ONE I NTELL I T ONE 200 PROB E 100 PROB E I NTELLI T ONE I NTELLI T ONE 200 PROBE 100 PROBE I NTELLI T ONE I NTELLI T ONE 200 PROBE 100 PROBE I NTE LLI T ONE I NTE LLI T ONE 2...

Page 14: ...ect unused test leads and connectors from the toner 3 Turn the toner s rotary switch to SERVICE 4 The LEDs indicate telephone service and polarity as shown in Figure 2 The toner checks for continuity...

Page 15: ...wered Use the toner s SERVICE function to check voice circuits for power Use a voltage meter to check other types of circuits for power 2 Turn off the toner 3 Connect the toner to the circuit or compo...

Page 16: ...ice circuit as shown in Figure 4 3 Turn the toner s rotary switch to E 4 Use the telephone test set for talking or other functions Validating Cable Maps with an IT200 Probe You can use the IT100 toner...

Page 17: ...oid damaging the case do not use solvents or abrasive cleansers Battery Life and Replacement The toner and probe batteries last for about 20 hours of typical use Figure 5 shows how to replace the batt...

Page 18: ...est list of IT100 accessories and other cable testers visit the Fluke Networks website at www flukenetworks com Table 2 Accessories Accessory Fluke Networks Model or Part Number Test lead set banana j...

Page 19: ...re 32 F to 104 F 0 o C to 40 o C Storage temperature 4 F to 140 F 20 o C to 60 o C Operating relative humidity RH without condensation 95 50 F to 95 F 10 o C to 35 o C 75 95 F to 104 F 35 o C to 40 o...

Page 20: ...one Battery type and life 9 V alkaline NEDA 1604A or IEC 6LR61 20 hours typical Auto power down Turns off automatically after 4 hours of inactivity IT100 Probe Electrical and Functional Specifications...

Page 21: ...alidation Shield validation Legacy 1 kHz tone Visual audible proximity indicators Requires IntelliTone IP200 probe Certifications and Compliance P Conforms to relevant European Union directives N10140...

Page 22: ...IT100 Users Manual 16...