Summary of Contents for i30

Page 1: ...imited Excellent Integrated System Limited Stocking Distributor Stocking Distributor Click to view price real time Inventory Delivery Lifecycle Information Click to view price real time Inventory Delivery Lifecycle Information Fluke Electronics Fluke Electronics I30 I30 For any questions you can email us directly For any questions you can email us directly sales integrated circuit com sales integr...

Page 2: ...designed for use with DMMs only Using advanced Hall Effect technology the i30s can accurately measure currents with a resolution of 1 mA from 5 mA to 30 A over the frequency range of DC to 100 kHz These features make it a powerful tool for use in inverters switch mode power supplies industrial controllers and other applications requiring current measurements and or waveform analysis Symbols The ta...

Page 3: ...l To avoid personal injury follow these precautions To avoid electric shock use caution during installation and use of this product high voltages and currents may be present in circuit under test Do not use the product if damaged Always connect probe to display device before it is installed around the conductor Always ensure the probe is removed from any live electric circuit and leads are disconn...

Page 4: ...d equipment installations such as distribution panels feeders and short branch circuits and the lighting systems in large buildings Specifications Electrical Characteristics All accuracies stated at 23 C 1 C Current range 20 A ACRMS or DC Measuring range 30 A Overload capacity 500 A Output sensitivity 100 mV A Accuracy at 25 C 1 of reading 2 mA Resolution 1 mA Typical output noise level 200 µVRMS ...

Page 5: ...ral Characteristics Maximum conductor size 19 mm diameter Output cable and connections i30s 2 m cable terminated with a BNC connector 50 Ohms supplied with a 4 mm safety adaptor i30 1 5 m cable terminated with a dual 4 mm banana safety plug Output zero Manual adjust via thumbwheel Operating temperature range 0 to 50 C Storage temperature range with battery removed 20 to 85 C Weight 290 g ...

Page 6: ...ated circuit com Website www integrated circuit com Typical Performance Plots Frequency in Hz Gain in dB 10 1 0 1 2 3 1000 i30s 100000 Frequency in Hz Gain in dB 10 100 0 00 0 50 1 00 2 00 1 50 2 50 3 00 1000 10000 i30 100000 ehr01 eps Typical Frequency Response Frequency in Hz 10 0 5 10 15 20 1000 i30s 100000 Phase Shift in Degrees ...

Page 7: ... 2 00 1 50 1 00 0 50 0 00 0 50 1 00 1 50 2 00 i30s 50 mA 5 10 15 20 25 30 A Error of Reading 2 00 1 50 1 00 0 50 0 00 0 50 1 00 1 50 2 00 i30 50 mA 5 10 15 20 25 30 A ehr03 eps Typical Accuracy Curve Safety Standards BS EN 61010 1 2001 BS EN 61010 2 032 2002 BS EN 61010 031 2002 CSA C22 2 No 1010 1 300 VRMS Category III Pollution degree 2 Use of the probe on uninsulated conductors is limited to 30...

Page 8: ...rier 6 Jaws 7 Battery Cover Screw Captive ehr04 eps Figure 1 i30s i30 AC DC Current Clamps W Warning To avoid injury when using the probe ensure that your fingers are behind the protective barrier as shown in Figure 1 Do not use the probe if any part of the probe including the lead and connector s appear to be damaged or if a malfunction of the instrument is suspected Clean the case periodically b...

Page 9: ...s required Positive output indicates that the current flow is in the direction shown by the arrow on the probe Battery Replacement W Warning To avoid personal injury always ensure the probe is removed from any live electric circuit and leads are disconnected before removing the battery cover Never operate the probe without the battery cover fitted The red LED will flash when the minimum operating ...

Page 10: ...behalf To obtain service during the warranty period contact your nearest Fluke authorized service center to obtain return authorization information then send the product to that Service Center with a description of the problem THIS WARRANTY IS YOUR ONLY REMEDY NO OTHER WARRANTIES SUCH AS FITNESS FOR A PARTICULAR PURPOSE ARE EXPRESSED OR IMPLIED FLUKE IS NOT LIABLE FOR ANY SPECIAL INDIRECT INCIDENT...

Page 11: ...lectronics Excellent Integrated System Limited Datasheet of I30 CLAMP CURRENT AC DC 30A Contact us sales integrated circuit com Website www integrated circuit com Powered by TCPDF www tcpdf org Powered by TCPDF www tcpdf org ...