![Fluke DTX-COAX Getting Started Manual Download Page 1](http://html1.mh-extra.com/html/fluke/dtx-coax/dtx-coax_getting-started-manual_2309134001.webp)
DTX-COAX Instruction Sheet/English
Page 1
PN 2404890 (English) November 2004
2004 Fluke Corporation. All rights reserved. Printed in USA.
All product names are trademarks of their respective companies.
DTX-COAX
Coaxial Interface Adapters
Getting Started Guide
The DTX-COAX coaxial adapters let you use a DTX CableAnalyzer
Series tester
to certify, troubleshoot, and document coaxial network and video cabling. The
coaxial adapters come with the accessories listed below. If something is
damaged or missing, contact the place of purchase immediately.
•
Two DTX-COAX adapters
•
Two female to female F-connector adapters
•
Short (12 in; 30 cm) male to male F-connector cable
•
Two F-connector female to BNC female adapters
Getting Started Testing Coaxial Cabling
Note
Turn on the tester and let it sit for 1 minute before setting the
reference. Set the reference only after the testers have reached an
ambient temperature between 10
°
C and 40
°
C (50
°
F and 104
°
F).
1
Attach coaxial adapters to the main and remote testers, screw in the
F-connector to BNC adapters; then connect the testers together using the
12-inch (30 cm) coaxial cable provided.
2
Turn the rotary switch to SPECIAL FUNCTIONS and turn on the smart
remote.
3
Highlight Set Reference; then press
H
. If both a fiber module and copper
adapter are attached, select Link Interface Adapter.
4
Press
P
.
-continued-