![Fluke DTX-1800 Technical Reference Handbook Download Page 75](http://html.mh-extra.com/html/fluke/dtx-1800/dtx-1800_technical-reference-handbook_2309247075.webp)
Tutorials on Setup and Test Procedures
Certifying Fiber Cabling
2-15
2
amd118f.eps
Figure 2-9. Self Test Connections for Fiber Modules
Step 3: Selecting a Fiber Type and Test Limit
Select the cable type and test limit specified for the job.
3-1 Turn the rotary switch to SETUP.
3-2 Use
D
to highlight Fiber Loss; then press
H
.
3-3 On the Fiber menu use
D
and
H
to select Fiber
Type. Fiber types are organized in groups:
•
Generic: Generic types of fiber
•
Custom: Fiber types entered by a DTX user
•
Manufacturer: Specific brands of fiber cable
3-4 Use
D
to highlight a group for the fiber type you
will test; then press
H
.
3-5 Use
D
to highlight the fiber type you will test; then
press
H
.
3-6 On the Fiber menu, use
A
to highlight Test Limit
(if it is not highlighted); then press
H
.
3-7 The first Test Limit screen shows the most recently-used
limits. To see the list of test limit groups, press
J
More.
3-8 Use
D
and
H
to select a different limit group, if
necessary, and to select the test limit required for the
job.
Summary of Contents for DTX-1800
Page 4: ......
Page 18: ...DTX Series CableAnalyzer Technical Reference Handbook xiv ...
Page 132: ...DTX Series CableAnalyzer Technical Reference Handbook 4 8 ...
Page 158: ...DTX Series CableAnalyzer Technical Reference Handbook 6 14 ...
Page 270: ...DTX Series CableAnalyzer Technical Reference Handbook 8 62 ...
Page 284: ...DTX Series CableAnalyzer Technical Reference Handbook 10 10 ...
Page 304: ...DTX Series CableAnalyzer Technical Reference Handbook 11 20 ...
Page 372: ...DTX Series CableAnalyzer Technical Reference Handbook A 8 ...
Page 374: ...DTX Series CableAnalyzer Technical Reference Handbook B 2 ...