2-1
Chapter 2: Tutorials on Setup and Test Procedures
The tutorials in this chapter guide you through setting up
the tester, checking the tester’s status, testing twisted pair
cabling, testing fiber cabling with the DTX-xFM2 fiber
modules, and setting up cable ID lists.
Preparing to Save Tests
Step 1: Checking the Memory Space Available
1-1 DTX-1800, DTX-1200: Insert a memory card into the
tester.
1-2 Turn the rotary switch to SPECIAL FUNCTIONS.
1-3 Use
D
to highlight Memory Status; then press
H
.
1-4 DTX-1800, DTX-1200: Press
J
Int. Memory to switch
between memory card and internal memory status.
Step 2: Entering Job Information
Job information includes the operator name, name of the
job site, and the customer’s company name. These settings
are stored with results you save.
To enter job information:
2-1 Turn the rotary switch to SETUP.
2-2 Use
D
to highlight Instrument Settings; then press
H
.
2-3 Press
C
to go to the tab with the Operator Name
setting. Press
H
to select Operator Name.
2-4 Press
J
Create; then use
JKL
,
BCAD
, and
H
to enter your name in the
box. Press
N
when you are done.
2-5 Figure 2-1 describes the text editing screen.
2-6 Use
D
to highlight Site; then press
H
.
-continued-
Summary of Contents for DTX-1800
Page 4: ......
Page 18: ...DTX Series CableAnalyzer Technical Reference Handbook xiv ...
Page 132: ...DTX Series CableAnalyzer Technical Reference Handbook 4 8 ...
Page 158: ...DTX Series CableAnalyzer Technical Reference Handbook 6 14 ...
Page 270: ...DTX Series CableAnalyzer Technical Reference Handbook 8 62 ...
Page 284: ...DTX Series CableAnalyzer Technical Reference Handbook 10 10 ...
Page 304: ...DTX Series CableAnalyzer Technical Reference Handbook 11 20 ...
Page 372: ...DTX Series CableAnalyzer Technical Reference Handbook A 8 ...
Page 374: ...DTX Series CableAnalyzer Technical Reference Handbook B 2 ...