Certifying Fiber Optic Cabling
Autotest in Smart Remote Mode
8-19
8
Figure 8-8. Equipment for Testing in Smart Remote Mode (1 Jumper Method)
amd46f.eps
A
Tester and smart remote with fiber modules and
connector adapters installed. Match connector adapters
to the connectors in the link.
B
Memory card (optional)
C
Two ac adapters with line cords (optional)
D
Test reference cords. Match the fiber to be tested. Long
ends must have SC connectors. For the other connectors,
match the connectors in the link.
E
Two singlemode adapters of the appropriate type
F
Two mandrels. Recommended when testing multimode
fiber with DTX-MFM2 modules. See page 8-12.
G
Fiber cleaning supplies
H
A microscope for inspecting fiber connectors (the FT500
FiberInspector Mini Video Microscope is shown)