DTX Series CableAnalyzer
Technical Reference Handbook
7-36
Figure 7-19. Event Table Features
amd129f.eps
A
Overall result for the test.
B
Events on the fiber, each event’s status, and the distance to each event. See
Table 7-3 on page 7-37.
E
: The event’s measured value is within the limit. A yellow checkmark
means there is a warning for the result. To see the warning, highlight the
event; then press
L
View Details.
i
: The event has no PASS/FAIL limit in the selected test limit. The
measurement is provided for informational purposes.
F
: The event’s measured value exceeds the limit.
C
Press
J
to view the OTDR trace.
D
Press
K
to view details for the highlighted event. See page 7-42.
1
2
3
D