Diagnosing Copper Cabling Faults
The HDTDR Analyzer
6-11
6
Figure 6-3. HDTDR Plot (permanent link adapters used)
amd97f.eps
A
The percentage of the HDTDR test signal reflected back to
the tester. See Figure 6-4. Reflections plotted are adjusted
to compensate for insertion loss. This means the plot
represents the magnitudes of signals at the reflection
source.
B
The beginning and end of the cabling under test. For a
permanent link, the plot shows some of the permanent
link adapter cable before and after the cabling under test.
C
Horizontal and vertical magnification levels for the
plot. In zoom mode, use
BC
and
AD
to
zoom in or out at the cursor’s location.
D
The distance to the end of the cabling.
E
The cursor and the distance to the cursor from the
tester. In cursor mode, use
BC
to move the cursor.
F
The reflection percentage at the cursor's location.
G
Shows the reflection plots by pair. Press
I
to return
to the plot of all pairs.
H
Toggles the display between zoom and cursor modes.
I
Sets or clears the measurement marker. See
J
.
J
The distance between the measurement cursors.
To use the measurement cursors (with the plot in
cursor mode):
1
Press
J
Clear Mark if necessary; then use
BC
to move the cursor to the beginning of an area
of interest. Use
AD
to zoom in on the
area if desired.
2
Press
J
Set Mark; then use
BC
to move the
second cursor to the end of the area of interest.
1
3
4
5
10
2
6
8
7
9
Summary of Contents for DTX-1800
Page 4: ......
Page 18: ...DTX Series CableAnalyzer Technical Reference Handbook xiv ...
Page 132: ...DTX Series CableAnalyzer Technical Reference Handbook 4 8 ...
Page 158: ...DTX Series CableAnalyzer Technical Reference Handbook 6 14 ...
Page 270: ...DTX Series CableAnalyzer Technical Reference Handbook 8 62 ...
Page 284: ...DTX Series CableAnalyzer Technical Reference Handbook 10 10 ...
Page 304: ...DTX Series CableAnalyzer Technical Reference Handbook 11 20 ...
Page 372: ...DTX Series CableAnalyzer Technical Reference Handbook A 8 ...
Page 374: ...DTX Series CableAnalyzer Technical Reference Handbook B 2 ...