In Static measurement mode, four 45° positions (10:30, 1:30, 4:30 and 7:30 o'clock position
as viewed towards the sensor) are available.
In Active Clock, the Live Move screen appears if the laser has been centered and the shafts are
rotated to any one of the four sectors.
In Static measurement mode, use
and
to place the displayed sensor at the
desired 45° position. This position corresponds to the actual angular position of the sensor and
reflector on the shafts. Tap
to confirm position. If the laser beam is centered, the Live
Move screen appears.
l
(1)
The selected Live Move plane (in this example 'H' – horizontal)
l
(2)
Arrows indicate direction and magnitude to move machine feet
l
(3)
Tolerance coded gap and offset coupling values
l
(4)
Tapping the 'Undo' icon allows user to re-measure or start Live Move afresh
l
(5)
Tapping the 'Proceed' icon allows user to re-measure or start Live Move afresh
Once Live Move has been detected, the 'Cancel' icon
replaces the 'Undo' icon
.
Note
To change the Live Move plane, tap the desired plane (in this example 'V' – vertical). A
hint appears requiring confirmation on whether to change plane or proceed with Live
Move in present plane.
SHAFTALIGN touch
79
On-board help
Summary of Contents for db PRUFTECHNIK SHAFTALIGN touch
Page 1: ...SHAFTALIGN touch On board help...
Page 2: ...SHAFTALIGN touch On board help Version 2 3 Edition 07 2020 Part No DOC 26 200 EN...
Page 24: ...SHAFTALIGN touch 23 On board help...
Page 42: ...After target values have been entered tap to proceed SHAFTALIGN touch 41 On board help...
Page 63: ...62 Version 2 3 On board help...
Page 127: ...W Wireless connection 21 X XY view 81 XY View 53 SHAFTALIGN touch 126 On board help...