Use the results mode carousel to select the desired results option then tap
to confirm
selection.
The following options are available:
l
‘Actual’ – used to show just the measured alignment values without regard to any target
values or thermal growth values that have been entered, even if they are active
l
‘Specification’ – shows just the effect of any target specifications and/or thermal growth
values that may have been entered and activated, from a baseline of zero, without
regard to any measured misalignment
l
‘Actual minus Specification’ – this option considers any specified coupling targets or
machine thermal growth, and is the default view. It is the option that should be used
when actually performing alignment corrections
Sign convention
Coupling gap is positive when open at top or side away from viewer. The viewer is considered
to be standing in front of the machines as they appear on the display.
Offset is positive when the right shaft axis is higher than the left shaft axis or further away
from the viewer than the left axis.
Both vertical and horizontal results show the foot position relative to the centerline of machine
designated stationary. Positive values indicate that machine is upwards or away from viewer.
Negative values indicate that machine is downwards or towards the viewer.
SHAFTALIGN touch
75
On-board help
Summary of Contents for db PRUFTECHNIK SHAFTALIGN touch
Page 1: ...SHAFTALIGN touch On board help...
Page 2: ...SHAFTALIGN touch On board help Version 2 3 Edition 07 2020 Part No DOC 26 200 EN...
Page 24: ...SHAFTALIGN touch 23 On board help...
Page 42: ...After target values have been entered tap to proceed SHAFTALIGN touch 41 On board help...
Page 63: ...62 Version 2 3 On board help...
Page 127: ...W Wireless connection 21 X XY view 81 XY View 53 SHAFTALIGN touch 126 On board help...