Static measurement
This measurement mode is used for uncoupled shafts, nonrotatable shafts and vertical foot-
mounted or flange-mounted machines.
If not yet completed, enter dimensions then center laser beam.
Use the measurement mode carousel and select static measurement mode (Static Clock).
l
(1)
'The 'left/right' navigation icons are used to position the displayed sensor and
reflector at an angular position corresponding to the actual position of the components
as mounted on the shafts.
l
(2)
On-screen hint to position displayed sensor and reflector then take measurement
point
Turn the shafts to any of the eight 45° positions (i.e. 12:00, 1:30, 3:00, 4:30, 6:00, 7:30, 9:00
or 10:30 o’clock position viewed from reflector towards sensor). Position shaft as accurately
as possible using either an external inclinometer or protractor. Tap the pulsating
M
or
to take the first measurement point.
l
(1)
Number of points already taken (in this example initial point)
l
(2)
Tap pulsating
M
to take next measurement
l
(3)
On-screen hint to position displayed sensor and reflector then take measurement
point
l
(4)
'Cancel' icon – used to cancel current measurement and start new measurement
Rotate shaft to the next measurement position. The displayed sensor and reflector must be at
the same angular position as the mounted components. Use
or
to position the
displayed sensor and laser then take next measurement point by tapping the pulsating
M
[
2
].
SHAFTALIGN touch
63
On-board help
Summary of Contents for db PRUFTECHNIK SHAFTALIGN touch
Page 1: ...SHAFTALIGN touch On board help...
Page 2: ...SHAFTALIGN touch On board help Version 2 3 Edition 07 2020 Part No DOC 26 200 EN...
Page 24: ...SHAFTALIGN touch 23 On board help...
Page 42: ...After target values have been entered tap to proceed SHAFTALIGN touch 41 On board help...
Page 63: ...62 Version 2 3 On board help...
Page 127: ...W Wireless connection 21 X XY view 81 XY View 53 SHAFTALIGN touch 126 On board help...