Tap (
1
) and select machine material. The corresponding linear thermal expansion appears.
Enter the three values [
2
] required to calculate the thermal growth value for the selected feet
pair using the onscreen keyboard [
3
]. The three values are:
l
Ambient temperature (initial temperature)
l
Machine running temperature (final temperature)
l
Distance from machine base (or shimming plane) to the shaft centerline (length)
With thermal growth values enabled [
4
], the corresponding machine within the mini train inset
at the top-right corner appears in orange [
5
].
Tap
to simultaneously display the calculated thermal growth value for the respective
feet pair [
6
] and toggle to the next feet pair [
7
].
Tap
to return to the thermal growth screen showing the calculated values.
Multiple feet
The item "Multiple feet" is primarily used to determine foot corrections in a multiple feet
machine, and is therefore accessible also in the result screen.
The dimension between the feet may be defined in the 'Multiple feet' screen which is accessed
by tapping the item "Multiple feet".
38
Version:2.3
On-board help
Summary of Contents for db PRUFTECHNIK SHAFTALIGN touch
Page 1: ...SHAFTALIGN touch On board help...
Page 2: ...SHAFTALIGN touch On board help Version 2 3 Edition 07 2020 Part No DOC 26 200 EN...
Page 24: ...SHAFTALIGN touch 23 On board help...
Page 42: ...After target values have been entered tap to proceed SHAFTALIGN touch 41 On board help...
Page 63: ...62 Version 2 3 On board help...
Page 127: ...W Wireless connection 21 X XY view 81 XY View 53 SHAFTALIGN touch 126 On board help...