Chapter 12: The OptiFiber Pro HDR OTDR Module
HDR OTDR Results
443
LIMIT
: The maximum loss allowed by the selected test limit for
each wavelength the tester used.
N/A
shows if there is no test
limit for the measurement.
MARGIN
: The difference between the limit and the measured
loss for each wavelength the tester used. Margin is negative if
the loss exceeds the limit.
N/A
shows if there is no test limit
for the measurement.
Tap
to see help for this screen.
To see details for the event before or after this one, tap
or
next to
Events
.
SEGMENT ATTENUATION
: This tab shows the attenuation
coefficient of the fiber segment before the event. This is the
attenuation per unit of length for the segment. This value
shows as
N/A
if the tester could not measure it accurately.
This can occur for short segments or if the connector before
the segment has too much tailing.
REFLECTANCE
: Reflectance is the return loss for one event. It
is the ratio of the light reflected at one point on the fiber to
the light that gets to that point from the source. Reflectance
values are in units of negative decibels. A smaller (more
negative) reflectance value shows that less light is reflected
back to the source. For example, a reflectance of -45 dB shows
for a good multimode connection. A reflectance of-20 dB
shows for a bad multimode connection that reflects more
light back to the OTDR.
Reflectances that exceed the measurement range of the tester
show a ">" (greater than) symbol. If any reflection shows ">",
ORL shows "<" (less than).
Reflectances from hidden events can possibly show “<" because
the tester cannot measure the backscatter before the event.
Summary of Contents for CableAnalyzer DSX-5000
Page 24: ...xxii Versiv Series Cabling Certification Product Family Technical Reference Handbook...
Page 34: ...xxxii Versiv Series Cabling Certification Product Family Technical Reference Handbook...
Page 220: ...Versiv Series Cabling Certification Product Family Technical Reference Handbook 184...
Page 268: ...Versiv Series Cabling Certification Product Family Technical Reference Handbook 232...
Page 330: ...Versiv Series Cabling Certification Product Family Technical Reference Handbook 294...
Page 338: ...Versiv Series Cabling Certification Product Family Technical Reference Handbook 302...
Page 592: ...Versiv Series Cabling Certification Product Family Technical Reference Handbook 556...
Page 604: ...Versiv Series Cabling Certification Product Family Technical Reference Handbook 568...
Page 620: ...Versiv Series Cabling Certification Product Family Technical Reference Handbook 584...
Page 672: ...Versiv Series Cabling Certification Product Family Technical Reference Handbook 636...
Page 676: ...Versiv Series Cabling Certification Product Family Technical Reference Handbook 640...
Page 688: ...Versiv Series Cabling Certification Product Family Technical Reference Handbook 652...