![Fluke CableAnalyzer DSP-4100 User Manual Download Page 82](http://html1.mh-extra.com/html/fluke/cableanalyzer-dsp-4100/cableanalyzer-dsp-4100_user-manual_2309836082.webp)
DSP-4000 Series
Users Manual
3-16
NEXT@REMOTE
The NEXT@REMOTE test and its results are identical to the NEXT test described
above, except that the NEXT@REMOTE measurements are taken from the remote
end of the cabling.
ELFEXT Test
The ELFEXT (equal level far-end crosstalk) test calculates the ratio of FEXT to
attenuation for each cable pair. To determine ELFEXT, the main unit first
measures FEXT by generating a signal at the far end of the cabling and measuring
the resulting crosstalk at the near end of the cabling. ELFEXT is calculated as the
difference (in dB) between the measured FEXT and attenuation values. If the
ELFEXT test fails, you can use the
F
key to locate sources of crosstalk on the
cabling.
Because ELFEXT values from either end of a cable are virtually identical, a
ELFEXT@REMOTE test is not required. (See Chapter 7 for more information.)
The first ELFEXT screen displays the cable pairs tested, the worst-case ELFEXT
margin, and the test result for each set of pairs.
To see detailed results for the cable pairs, use
D U
to highlight the pairs; then
press
@
View Result
. Table 3-4 describes the items on the ELFEXT
results screen.
Summary of Contents for CableAnalyzer DSP-4100
Page 10: ...DSP 4000 Series Users Manual viii...
Page 20: ...DSP 4000 Series Users Manual 1 8...
Page 66: ...DSP 4000 Series Users Manual 2 46...
Page 99: ...Autotest The Autotest Report 3 3 33 oy82f bmp Figure 3 12 Autotest Report in Tabular Format...
Page 138: ...DSP 4000 Series Users Manual 6 6...
Page 170: ...DSP 4000 Series Users Manual 7 32...
Page 195: ...Appendices Appendix Title Page A Tests Supported by LIAs A 1 B Glossary B 1...
Page 196: ......
Page 210: ...DSP 4000 Series Users Manual B 12...
Page 216: ...DSP 4000 Series Users Manual 6...