![Fluke CableAnalyzer DSP-4000 Series User Manual Download Page 98](http://html1.mh-extra.com/html/fluke/cableanalyzer-dsp-4000-series/cableanalyzer-dsp-4000-series_user-manual_2309835098.webp)
DSP-4000 Series
Users Manual
4-8
HDTDX Analyzer Plot
To view a HDTDX analyzer plot for a set of cable pairs, use
D U
to highlight
the pairs, then press
#
View Plot
to see the plot screen for the pairs. Figure
4-2 describes an example of a HDTDX analyzer plot.
3
4
1
2
5
oy20c.eps
1
The cable pairs relevant to the results.
2
The distance along the cable under test. The 0 at the left of the scale represents the
location of the main test tool.
3
Magnitude of crosstalk on the cable pair. A peak over 50 indicates a crosstalk level that
exceeds the limit specified by the selected test standard. Crosstalk levels are adjusted
to compensate for cable attenuation.
4
The Cursor Readout shows the distance to the crosstalk source at the cursor’s
position. The cursor aligns to the highest crosstalk peak. Use
L R
to move the cursor
left or right.
5
Use
D U
to change the maximum distance of the horizontal scale.
Figure 4-2. Example of an HDTDX Analyzer Plot for a Good Twisted Pair Cable Run
Summary of Contents for CableAnalyzer DSP-4000 Series
Page 6: ...DSP 4000 Series Users Manual iv...
Page 8: ...DSP 4000 Series Users Manual vi...
Page 18: ...DSP 4000 Series Users Manual 1 8...
Page 60: ...DSP 4000 Series Users Manual 2 42...
Page 128: ...DSP 4000 Series Users Manual 6 6...
Page 160: ...DSP 4000 Series Users Manual 7 32...
Page 186: ...DSP 4000 Series Users Manual 8 26...
Page 188: ...DSP 4000 Series Users Manual...
Page 204: ...DSP 4000 Series Users Manual B 14 oy81f bmp Figure B 5 Autotest Report in Graphical Format...
Page 210: ...DSP 4000 Series Users Manual B 20...
Page 222: ...DSP 4000 Series Users Manual C 12...