Table 7-1. Identifying Cable Faults
Test Failure
Likely Causes of Failure
Wire map: open
Wires connected to wrong pins at connector or punchdown
blocks.
Faulty connections.
Cables routed to the wrong location.
Wires broken by stress at connections.
Damaged connector.
Cuts or breaks in cable.
Wire map: split pair
Wires connected to wrong pins at connector or punchdown
blocks.
Wire map: reversed pairs
Wires connected to wrong pins at connector or punchdown
blocks.
Wire map: crossed pairs
Wires connected to wrong pins at connectors or punchdown
blocks.
Mix of 568A and 568B wiring standards (1, 2 and 3, 6 crossed).
Crossover cables used where not needed (1, 2 and 3, 6 crossed).