Fluke 985 Getting Started Manual Download Page 1

 

PN 4136462 

March 2012 

© 2012 Fluke Corporation. All rights reserved. Printed in U.S.A. Specifications are subject to change without notice. 
All product names are trademarks of their respective companies. 

985 

Airborne Particle Counter 

Getting Started

Summary of Contents for 985

Page 1: ...2 2012 Fluke Corporation All rights reserved Printed in U S A Specifications are subject to change without notice All product names are trademarks of their respective companies 985 Airborne Particle Counter Getting Started ...

Page 2: ... nearest Fluke authorized service center to obtain return authorization information then send the product to that service center with a description of the difficulty postage and insurance prepaid FOB Destination Fluke assumes no risk for damage in transit Following warranty repair the product will be returned to Buyer transportation prepaid FOB Destination If Fluke determines that failure was caus...

Page 3: ...ty Information 2 Battery 3 Product Overview 3 The Buttons 5 Product Connections 6 Charge Base Connections 7 Product Test 8 How to Purge the Product Sensor 8 How to Take a Sample 8 Navigation Menu 9 Sample Setup Submenus 9 Communication Setup Submenus 10 Sample Screen Menu 10 ...

Page 4: ...985 Getting Started ii Maintenance 11 Specifications 12 General 12 Environmental 13 ...

Page 5: ...nual on the Product CD for complete use instructions How to Contact Fluke To contact Fluke call one of the following telephone numbers Technical Support USA 1 800 44 FLUKE 1 800 443 5853 Calibration Repair USA 1 888 99 FLUKE 1 888 993 5853 Canada 1 800 36 FLUKE 1 800 363 5853 Europe 31 402 675 200 Japan 81 3 6714 3114 Singapore 65 6799 5566 Anywhere in the world 1 425 446 5500 Or visit Fluke s web...

Page 6: ...ls can focus the laser and be dangerous to the eye Do not use the Product if it operates incorrectly Read the entire Users Manual before using the Product Table 1 tells you about symbols used on the Product and in this manual Table 1 Symbols Symbol Description W Risk of Danger Important information See Manual X Hazardous voltage Risk of electrical shock Do not dispose of this product as unsorted m...

Page 7: ...t on the Charge Base An amber light on the front of the Charge Base shows that the base is powered The light changes to green when the Product is connected to the base If the ac adapter cord is connected to the Product a green light shows above the power jack If the Product is on the battery icon flashes as the battery charges The icon is solid does not flash when the battery is fully charged Appr...

Page 8: ...985 Getting Started 4 1 2 7 8 9 10 6 12 11 3 4 5 gud003 eps Figure 1 Product Components ...

Page 9: ...buttons For more information on the buttons see the Operation section Table 3 Buttons Button Description Power Push to turn the Product ON Push again and hold for 3 seconds to turn the Product OFF Menu Push to access the Product menus The Menus are Sample Screen Buffered Data Screen Sample Setup Communication Setup and Trend Data Sample Setup and Communication Setup also have submenus Enter Select...

Page 10: ...f the Charge Base The Ethernet connection is only available on the base Table 4 and Figure 2 show you the Product connections Table 4 Product Connections Item Description A Power Charge LED B USB Port C Base Input D Flash USB drive Port E Tripod Mount F DC Power Input 3 2 6 4 5 1 gud001 eps Figure 2 Product Connections ...

Page 11: ...s are also on the rear of the Charge Base The Ethernet connection is only available on the base Table 5 and Figure 3 show you these connections Table 5 Charge Base Connections Item Description A Ethernet Port B DC Power Input C USB Port 12V 1 2A 3 2 1 gud006 eps Figure 3 Charge Base Connections ...

Page 12: ...nt operation to be verified No more than 1 particle 0 3 μm in 5 minutes How to Purge the Product Sensor Particles must be purged removed from the Product sensor before use in a clean room or clean environment and after each high sampling count To purge the sensor 1 Attach the adapter and the Zero Count Filter 2 Set the Product to sample continuously set the Count Mode to Cumulative 3 Start the cou...

Page 13: ...us See Table 6 The Sample Setup and Communication Setup menus also have submenus See the Sample Setup Submenus section of the Users Manual Table 6 Main Menu Icons Icon Menu Item Sample Screen Buffered Data Screen Sample Setup Communication Setup Trend Data Sample Setup Submenus The Sample Setup Menu includes three submenus Submenu icons are shown in Table 7 and the subsequent sections tell you abo...

Page 14: ...l you about these submenus Table 8 Communication Submenu Icons Icon Submenu Item General Setup Diagnostics Login Sample Screen Menu The sample screen is the default screen that shows after the Product is turned on The screen shows the current sample settings as you take samples Push or to select from loaded locatons See Figure 4 samplescreen jpg Figure 4 Sample Screen ...

Page 15: ...parts Do not put battery cells and battery packs near heat or fire Do not put in sunlight Do not disassemble or crush battery cells and battery packs For safe operation and maintenance of the product Repair the Product before use if the battery leaks Connect the battery charger to the mains power outlet before the Product Do not keep cells or batteries in a container where the terminals can be sho...

Page 16: ... Zero Count Level 1 count 5 minute per JIS B9921 Concentration Limits 10 at 4 000 000 per cubic ft per ISO 21501 Count Mode raw counts ft3 m 3 l in cumulative or differential mode Data Storage 10 000 records rotating buffer Delay Time 0 hours to 24 hours Sample Inlet Isokinetic Probe Security Adminstrator password controlled optional Communication Modes USB or Ethernet Display QVGA color with back...

Page 17: ...perating Temperature 10 C to 40 C 50 F to 104 F Operating Altitude up to 6000 ft ASL Storage Humidity up to 98 RH non condensing Storage Temperature 10 C to 50 C 14 F to 122 F Power AC Adapter 100 to 240 Vac 12 Vdc 2 5 A Battery Type LI Ion 7 4 V 2600 mAh Charge time 3 5 hours Battery Duration 5 hours continuous sampling 10 hours with typical use model Agency Approvals P ...

Page 18: ...985 Getting Started 14 ...