background image

The new Fluke 87V has improved measurement functions, trouble-

shooting features, resolution and accuracy to solve more problems  

on motor drives, in plant automation, power distribution, and electro-

mechanical equipment. The 87V operates very similar to the classic 

87, but with more problem-solving power, safety, convenience and 

impact protection.

Features for maximum productivity

  Unique function for accurate voltage and frequency measurements 

on adjustable speed motor drives and other electrically noisy 

equipment (87V)

  Built-in thermometer conveniently allows you to take temperature 

readings without having to carry a separate instrument (87V)

  Large digit display with bright, two-level backlight makes the  

80 Series V significantly easier to read than older models

NEW!

 87V/E2 Industrial Electrician Combo Kit makes troubleshooting 

more productive with standard meter hanging accessory for hands-

free operation, soft case for protection and storage, 1.5 m  

heat resistant silicone test leads and more.

Electrical safety

All inputs are protected to Category III, 1000 V and Category IV  

600 V. They can withstand impulses in excess of 8,000 V and  

reduce risks related to surges and spikes.

  Function 

Range and resolution 

Basic accuracy

   

 

83V 

87V

  DC Volts 

600.0 mV, 6.000 V, 60.00 V, 

   

600.0 V, 1000 V 

0.1 % 

0.05 %

  AC Volts 

600.0 mV, 6.000 V, 60.00 V, 

0.5 % 

0.7 % 

   

600.0 V, 1000 V 

 

(True-rms)

  DC Current 

600.0 µA, 6000 µA, 60.00 mA, 

   

600.O mA, 6.000 A, 10.00 A 

0.4 % 

0.2 %

  AC Current 

600.0 µA, 6000 µA, 60.00 mA, 

1.2 % 

1.0 % 

   

600.O mA, 6.000 A, 10.00 A 

 

(True-rms)

  Temperature 

-200 to 1090 °C (-328 to 1994 °F) 

— 

1.0 % 

  (excl. probe)

  80BK Temperature 

-40 to 260 °C (-40 to 500 °F) 

— 

2.2 °C 

  Probe 

 

 

or 2 %

  Resistance 

600.0 

W, 

6.000 k

W, 

60.00 k

W, 

   

600.0 k

W, 

6.000 M

W, 

50.00 M

0.4 % 

0.2 %

  Capacitance 

10.00 nF, 100.0 nF, 1.000 µF, 

   

10.00 µF, 100.0 µF, 9,999 µF 

1.0 % 

1.0 %

  Frequency 

199.99 Hz, 1.9999 kHz, 

   

19.999 kHz, 199.99 kHz 

0.005 % 

0.005 %

80 Series V Industrial  

True-RMS Multimeter  

with Temperature

Specifications

Accuracy and diagnostic functions for 

maximum industrial productivity

  

E

le

ct

rical Safe

ty

 

1000 V CAT III

600 V CAT IV

N10140