![Fluke 6200-2 User Manual Download Page 13](http://html1.mh-extra.com/html/fluke/6200-2/6200-2_user-manual_2310366013.webp)
Appliance Tester
Features
5
Pushbuttons
Use the pushbuttons in Table 4 to control operation of the Tester.
Table 4. Pushbutton Controls
MEM
CLEAR
BOND
200 mA
BOND
25 A
INSUL-
ATION
I
SUB
LOAD/
LEAK
I
TOUCH
IEC
LEAD
ZERO
1
2
4
3
5
6
7
8
9
10
11
12
hdc09.eps
No. Function No. Function
Start the 200 mA Earth Bond test
Clear stored data
Start the high current Earth Bond test
Print test results
Start the combined Load/Earth Leakage
Current test
Start zeroing the Earth Bond test
Start the Insulation test
Start the IEC Lead test
Start the Touch Current test
Start the Substitute Leakage Current test
Store test results
Stop the current action and return to idle
screen
Beeper
The Tester can make several types of beeper sounds, see Table 5.
Table 5. Beeper Sounds
Sound Explanation
Click
A button is pushed.
1 beep
A test passed.
2 beeps close together
- A test failed.
- Warning, see display.
- The STOP button is pushed, the current action is stopped.
1 long beep
A continuous non-live test has been started.
2 beeps + 1 long beep
A continuous live test has been started.
Continuous 2 tone sound
Dangerous condition! Unplug the unit immediately!
Summary of Contents for 6200-2