N414-P 

panel mount BATCH-CONTROLLER 

with NTEP certification and RECEIPT PRINTER DRIVER 
 

 
 
Signal input flowmeter: Pulse 

 Coil, NPN, PNP, Reed, Namur, Active 

Control input:   Five inputs for remote control. 
Control output:  Five outputs to control valves, pumps and alarms 
Communication: Printer interface for receipt printing 

 

Save time and cost with the user-friendly batch controller.  

More info: www.fluidwell.com/nseries 

Summary of Contents for N414-P

Page 1: ...VER Signal input flowmeter Pulse Coil NPN PNP Reed Namur Active Control input Five inputs for remote control Control output Five outputs to control valves pumps and alarms Communication Printer interf...

Page 2: ...nion Whilst the WEEE Directive may not apply to your region we support its policy and ask you to be aware on how to dispose of this product The crossed out wheelie bin symbol illustrated and found on...

Page 3: ...s and requirements set by the authorities the manufacturer the employer and the plant owner are allowed to do the electrical work UNINTENDED USE A hazardous situation may occur if the N SERIES is not...

Page 4: ...actions or procedures which if not performed correctly may lead to personal injury a safety hazard or damage of the N414 P or connected instruments A caution indicates actions or procedures which if n...

Page 5: ...stall the unit into the cabinet panel 16 3 3 Electrical installation 16 3 3 1 Introduction 16 3 3 2 Voltage selection sensor supply 17 3 3 3 Terminal connectors 17 4 Configuration 23 4 1 Introduction...

Page 6: ...and DC applications Wide range of inputs outputs and functions for any application Fig 1 Schematic overview functions N414 Flowmeter input One flowmeter a passive or active pulse Namur or coil signal...

Page 7: ...ormation etc Power failure Information will not be lost in the event of power failure all settings are stored in EEPROM memory a just in time backup is built in to write the latest batch information a...

Page 8: ...ceipt is printed on an external device Additional receipts can be printed on demand and will show DUPLICATE on the ticket Below examples show printed receipts The arrows indicate the items that can be...

Page 9: ...and a compression seal it is not possible to access the W M switch It is also not possible to remove the N414 P from the cabinet panel The certified lock wire and the compression seal are not included...

Page 10: ...twice to display the accumulated total COUNT to display the number of fully executed batches PRINT to print a receipt During editing of the receipt header this key is used to move the cursor to the le...

Page 11: ...set Tank fill symbol The batch process can be visualized with the tank fill symbol This graphical representation can be enabled or disabled When the batch overfills the preset quantity by 2 5 the grap...

Page 12: ...When the TOTAL key is pressed once the resettable total will be displayed After pressing this key again the accumulated total will be displayed The accumulated total cannot be reset The value will co...

Page 13: ...continued or terminated See Interrupting and ending the batch process External alarm The N414 P can receive an external alarm during a batch This can be set with SETUP 7 1 Alarm When the alarm is act...

Page 14: ...ng positions are available one on the top side photo and one on the bottom side Use the supplied M4 x 6mm thread forming screw with a lock washer 3 1 1 GENERAL INSTALLATION OVERVIEW This overview give...

Page 15: ...exposed to harsh unnecessary harsh weather conditions When used in extreme cold surroundings or varying climatic conditions take the necessary precautions against moisture by placing a dry sachet of...

Page 16: ...rity some parts are not shown or numbered 3 3 ELECTRICAL INSTALLATION 3 3 1 INTRODUCTION Make sure the installation is made safe and the activities are approved by the responsible person Lock out Tag...

Page 17: ...de for a shielded twisted pair cable which meets at least the Category 5 cable standard 3 3 3 TERMINAL CONNECTORS The following terminal connectors are available Fig 15 Overview of terminal connectors...

Page 18: ...signal input typical Reed switch The N414 P is suitable for use with flowmeters which have a reed switch To avoid pulse bounce from the reed switch it is advised to select REED LP low pass filter rea...

Page 19: ...es an active signal read chapter 3 The detection levels are 50 of the selected supply voltage approx 4V 8 1 DC or 6V 12 DC or 12V 24 DC Fig 20 Terminal connections Active signal input typical Pulse si...

Page 20: ...switched with a potential free contact to the GND terminal number 8 for at least 100msec Fig 23 Terminal connections External hold typical Terminal 8 11 External control Reset Batch With this function...

Page 21: ...nal 13 14 Transistor 1 output OT1 The schematic is given for transistor output OT1 For clarity transistor output OT 2 terminal 15 and transistor output OT3 terminal 16 are not illustrated The function...

Page 22: ...l the batch process Relay 1 is switched on during the whole batch process Max Switching capacity resistive load 8A 250V AC 30V DC Max Switching power resistive load 2000VA 240W Fig 28 Terminal connect...

Page 23: ...ity cap shall be installed and secured with a certified wire and a compression seal 4 2 1 GENERAL Configuration of the N414 P is done at SETUP menu SETUP menu is reached by pressing the PROG ENTER key...

Page 24: ...en data is altered but ENTER is not pressed then the alteration can still be cancelled by waiting for 20 seconds or by pressing ENTER for three seconds the PROG procedure will be abandoned automatical...

Page 25: ...reed reed lp pnp pnp lp Namur Coil hi 6 2 UNIT L m3 USGAL IGAL ft3 bbl kg ton US ton lb 6 3 K FACTOR 0 000010 9999999 7 CONTROL 7 1 BATCH RELAY 2 Off batch preclose alarm pulse external alarm pump 7 2...

Page 26: ...larger as 8999999 or with decimals cannot be set 4 2 4 EXPLANATION OF SETUP 2 OVERRUN Below parameters are metrologically relevant thus mechanically secured with the W M switch Due to system parameter...

Page 27: ...of 50 or more pulses CUT OFF 3 5 With the cut off time you determine a minimum flow requirement thresh hold if during this time less than XXX pulses SETUP 3 4 are generated the flowrate will be displ...

Page 28: ...units for Preset and Flowrate are derived from this setting The following can be selected Volumetric L m3 USGAL IGAL ft3 bbl Mass kg ton US ton lb Based on the selection for a volumetric or mass unit...

Page 29: ...ening the valve With value zero 0 this function is disabled PRECLOSE 7 6 According to the setting Preclose the switch off moment of the output is based on the remaining quantity before the end of batc...

Page 30: ...time a receipt is printed If a form feed is not required select disable DATEFORMAT 8 A This setting is used to define the format in which the date is to be printed YY MM DD or MM DD YY or DD MM YY TO...

Page 31: ...ity to change the batch value All the complete keyboard is locked except SETUP functionality Off this lock function is disabled The functions available from the cable terminals remain in use TAG NR 9...

Page 32: ...and buttons The input output wiring for reliability and aging symptoms The process accuracy As a result of wear and tear re calibration of the flowmeter might be necessary Do not forget to re enter a...

Page 33: ...10 Watt 24V DC 10 Power consumption max 10 Watt Sensor excitation Terminal 5 12V DC Iout max 30mA Terminal 29 8 2 12 or 24V DC Terminal 31 1 2 or 3V DC for sensor with low power consumption Coil Reed...

Page 34: ...preset value Start hold and stop the batch process Total can be reset to zero End of batch receipt printing Displayed information Preset value Running batch total or remaining quantity Total and accum...

Page 35: ...and the flowmeter The password is unknown If the password is not 1234 there is only one possibility left call your supplier ALARM When the alarm flag starts to blink an alarm condition has occurred Pr...

Page 36: ...FW N414 P M_v0203_01_EN docx Page 36 APPENDIX C DECLARATION OF CONFORMITY...

Page 37: ...receipts 8 Fig 5 W M switch and seal 9 Fig 6 W M Config Oper selection 9 Fig 7 Control Panel 10 Fig 8 Example display information during programming preset value 11 Fig 9 Example display information...

Page 38: ...E 3 1 unit L 3 2 time min 3 3 decimals 0000000 3 4 calculation 10 pulses 3 5 cut off 30 0 sec 4 ALARM 4 1 no flow disabled 4 2 flowrate time 10 0 sec 5 DISPLAY 5 1 display increase 5 2 tank enabled 5...

Page 39: ...linetermination CR LF 8 7 startrow 2 8 8 endrow 4 8 9 formfeed disable 8 A dateformat YY MM DD 8 B total print 8 C speed 9600 9 OTHERS 9 1 model N414 P N414 P N414 P 9 2 sw version 03 03 xx 9 3 serial...

Page 40: ...40 Fluidwell B V PO box 6 Voltaweg 23 Website www fluidwell com 5460 AA Veghel 5466 AZ Veghel Find your nearest representative www fluidwell com representatives The Netherlands The Netherlands Copyri...

Reviews: