![Fluidwell F013-A Manual Download Page 15](http://html1.mh-extra.com/html/fluidwell/f013-a/f013-a_manual_2308985015.webp)
Page 15
FW-F013-A-M_v0404_01_EN.docx
3.3.5
EXPLANATION OF SETUP-MENU 4 - DISPLAY
SETUP
FUNCTIONS
AND
VARIABLES
4
DISPLAY
4.1
FUNCTION
The large 17mm digits can be set to display total or flow rate.
When "total" is selected, both total and flow rate are displayed
simultaneously.
When "flow rate" is selected, only flow rate will be displayed with its
measuring unit while total will be displayed after pressing SELECT.
4.2
SET ALARM
This function determines if the flow rate alarm values can be set at
both Operator level and SETUP-level or SETUP-level only.
If SETUP has been selected, the alarm values are still visible for the
Operator but cannot be changed.
The functions below will only effect the optional LED-backlight.
4.3
BACKLIGHT (optional)
If a LED backlight has been supplied, it can be turned on or off.
4.4
BACKLIGHT ALARM
(optional)
In case the F013-P generates a flow rate alarm, the backlight can be
set to change to red. Following selections are available:
OFF:
during flow rate alarm the display is according to SETUP 4.3
ON:
during flow rate alarm the color is red.
FLASH: during flow rate alarm the color flashes red.
4.5
BRIGHTNESS (optional)
The backlight brightness is adjustable. The following can be selected:
1
– 5 (where 1 is minimum and 5 is maximum brightness)
3.3.6
EXPLANATION OF SETUP-MENU 5 - POWER MANAGEMENT
When used with the internal battery option, the user can expect reliable measurement over a long
period of time. The F013-A has several smart power management functions to extend the battery life
time significantly. Two of these functions are available.
SETUP
FUNCTIONS
AND
VARIABLES
5
POWER MANAGEMENT
5.1
LCD NEW
The calculation of the display-information influences the power
consumption significantly. When the application does not require a
fast display update, it is
strongly advised
to select a slow refresh
rate. Please understand that NO information will be lost; every pulse
will be counted and the output signal will be generated in the normal
way. The following can be selected:
Fast - 1 sec - 3 sec - 15 sec - off.
Example battery life-time:
•
FAST update: about 3 years.
•
1 sec update: about 5 years.
After a button has been pressed by the operator - the display refresh
rate will always switch to FAST for 30 seconds. When "OFF" is
selected, the display will be switched off after 30 seconds and will be
switched on as soon as a button has been pressed.
5.2
BATTERY MODE
The F013-A has two modes: operational or shelf. After "shelf" has
been selected, the F013-A can be stored for several years; it will not
process the sensor signal; the display is switched off but all settings
and totals are stored. In this mode, power consumption is extremely
low. To wake up the F013-A again, press the SELECT/
key twice.