8
ANALOG OUTPUT
DEFAULT
8.1
OUTPUT
enable, disable
disable
8.2
RATE MIN (4MA)
0.000 - 9999999
0
8.3
RATE MAX (20MA)
0.000 - 9999999
99999
8.4
CUT-OFF
0.0 - 9.9 %
0.0 %
8.5
TUNE MIN (4MA)
0000 - 9999
-
8.6
TUNE MAX (20MA)
0000 - 9999
-
8.7
FILTER
01 - 99 (01 = off)
01
9
PULSE OUTPUT
DEFAULT
9.1
MODE
disable, scaled, retransmit
disable
9.2
WIDTH
0.000 - 9.999 sec (0.000 = off)
0.000
9.3
AMOUNT
0000.000 - 9999999 per pulse
1000 L per
pulse
10
MODBUS COMMUNICATION
DEFAULT
10.1
SPEED
1200, 2400, 4800, 9600, 9600HP, 19200, 38400
9600
10.2
ADDRESS
001 - 247
1
10.3
MODE
off, bus asc, bus rtu
bus rtu
10.4
DATABITS
8 bits, 7 bits
8 bits
10.5
PARITY
none, even, odd
none
11
OTHERS
DEFAULT
11.1
MODEL
-
-
11.2
SOFTWARE VERSION
xx.xx.xx
-
11.3
SERIAL NUMBER
xxxxxxx
-
11.4
TIME
00:00:00 - 23:59:59 (hh.mm.ss)
00:00:00
11.5
PASSWORD
0000 - 9999 (0000 = off)
0000
11.6
KEY LOCK
enable, disable
enable
11.7
TAG NUMBER
0000000 - 9999999
0000000
5.5
SETUP MENU EXPLANATIONS
5.5.1
MENU 1: TOTAL
First set up the flowmeter in
4: FLOWMETER
as this directly affects the settings/measurement units in
the
Total
menu.
If the measurement unit is changed in
4.2: FLOWMETER > UNITS
, the unit in
1.1: TOTAL > UNIT
will change to
the default setting.
When a different unit is selected, the actual total values are NOT recalculated.
1
TOTAL
1.1 UNIT
Determines the measurement unit for total, accumulated total, and the
scaled pulse output.
The available measurement units are controlled by the units selected in
4.2: FLOWMETER > UNITS
:
Auto-vol: L – m3 – US gal – I gal – cf – Oil bbl – nL – nm3;
Auto-mas: kg – ton – US ton – lb
Hand: l – m3 – US gal – I gal – cf – Oil bbl – kg – ton – US ton – lb – nL –
nm3 – ---- (no unit).
1.2 DECIMALS
Determines for Total and Accumulated Total the number of digits after the
decimal point.