User manual D030-P Batch Controller
I
NTRODUCTION
– 1
FW-D030-P-MAN-EN-V0102_02
3
Available D030-P configurations
Your D030-P model is available in a number of hardwired configuration options.
A product label on the backside of the unit identifies which configuration options are included in
your D030-P.
The following table identifies the options that may apply to your D030-P.
Note:
A combination of configuration options is not always possible: some options rule others
out and some options require others to be included. Consult the product label on your
D030-P enclosure to see which options are included on your particular unit.
Standard confuguration: D030-P-HB-OT-PX-ZX
Coding information
D030-_
-HB -O_ -P_ -Z_
flowmeter input signal(s)
P
Pulse (coil, NAMUR, npn, pnp, reed switch)
Front Panel mount enclosure - IP66/67 (NEMA4X)
HB
Aluminum DIN 43700 / IEC 61554 front panel
Control output
OH
Active and passive transistor output - requires PD (DC). (PD (AC) and PM are pending).
OR
Highly isolated mechanical relay output - requires PD (DC). (PD (AC) and PM are pending
OT
Passive transistor output - standard configuration.
Power supply
PB
Long life lithium battery
PD
24V DC/AC + sensor supply.
PM
115 - 230V AC + sensor supply.
PX
Basic power supply 8 - 30V DC
Other options
ZB
Backligh, Bi-colort green/amber
ZF
Extra high sensitive coil input: 10mV p-p
ZG
Very high sensitive coil input: 5mV p-p
ZX
No options