INST 385 E35 SALT CHLORINE GENERATOR (10-2018)
5
WARNING:
It is essential that pipe work and equipment do not allow gases generated from the Cell to collect and build up.
WARNING
:
Cell must be installed Horizontal with water connections pointing downwards – this creates a safety gas
trap. Installation in any other way may cause explosion, injury or death.
WARNING:
Cell must be installed in the return pipework to the pool. Always install after filter, gas heater, and solar
heater or heat pump connections.
WARNING
:
DO NOT install isolation valves on inlet or outlet of cell.
Once the Cell is located, connect the black multi-core cable to the cell. The blue wire must be connected to the blue
terminal. The cable is designed to come from below the cell. Make sure wing nuts are correctly tightened to ensure
good contact.
POOL PREPARATION
Salt should always be added at the shallow end of the pool and allowed to dissolve. Running the pump will mix the
water and speed the dissolving process.
WARNING
: Never add salt to the skimmer box!!
NOTE:
Run the pump for 8-10 hours to ensure the salt is dissolved prior to running the Salt Chlorine Generator.
When the salt is dissolved, run the Pump and Salt System and run it on maximum chlorine output. Check that low salt is
not indicated on the Low Salt indicator Light. If it is, check again in 24 hours. If the low salt indicator still persists, have
the salt level checked by your local pool shops and ensure it is increased to 3,200 ppm.