background image

+

OR

SHANK/

CONE

WASHER

COUPLING

NUT

REFILL CLIP

OR ANGLE

ADAPTER

LOCKNUT

Roller & Hose

Clamp

ASSEMBLY PARTS

LEAK SENTRY 

DEVICE

Roller & Hose Clamp

4

2

0

6 8

Hose Clamps

MEASURE

HEIGHT ONLY; DO

NOT INSTALL

“CL”

MARK

1"

DO NOT

MOVE 

LOCK RING 

FLUIDMASTER

®

 400LS FILL 

VALVE WITH LEAK SENTRY

®

 

TECHNOLOGY INSTALLATION

INSTRUCTIONS

START HERE

IMPORTANT: A flapper with a plastic or metal chain is 

recommended for the Leak Sentry

®

 to maintain its settings. 

Flappers with nylon or vinyl straps will stretch and cause 
Leak Sentry

®

 to work improperly.

(Replace with a flapper like the Fluidmaster 501 or 502.)

Flush out tank and sponge 

dry. Remove water supply 

coupling nut and locknut 

from under tank.

Remove fill valve from tank.

Turn off water supply. 

(Clockwise)

1. 

PART#4-753, Rev. 3, 02/09

DO NOT USE

TOOLS NEEDED

Push the cone washer out with 

your thumb or with scissors

cut the four connections 

between the shank & cone

washers. Set cone washer aside.

Prepare Valve 

for Installation

2. 

N

O

 B

LE

ACH DROP

-IN

S

N

O

 B

LEA

CH DR O

P-

IN

S

DO NOT USE IN-TANK DROP-IN TOILET BOWL CLEANERS CONTAINING 

BLEACH OR CHLORINE.

 Use of such products will: 

(1) RESULT IN DAMAGE

 to tank 

components and 

MAY CAUSE FLOODING

 and 

PROPERTY DAMAGE

 and 

(2) VOID 

FLUIDMASTER WARRANTY. DO NOT

 overtighten nuts or tank/bowl may crack.

Fluidmaster Flush ’n Sparkle

®

 Toilet Bowl Cleaning System

 is recommended for 

those choosing to use in-tank bowl cleaners and 

WILL NOT VOID

 the 

FLUIDMASTER WARRANTY

 because 

it will not damage the components.

400LS WATER-SAVING FEATURES

Prevents wasteful refills in leaky tanks.

The Leak Sentry

®

 device alerts you to a tank leak, typically caused by a faulty flapper. 

If there is a tank leak, the float cup will not drop to refill the tank until the tank lever is 

pushed. On the first flush attempt, the valve will simply refill the empty tank; only then 

will you receive a complete flush. This will continue to occur until the tank leak is fixed.

The Adjustable Refill allows you to adjust the amount of water going into the bowl, 

eliminating water waste due to the bowl being overfilled.

   WARNING

Because drop-in cleaners used in the tank can result in damaged

tank parts (see WARNING above), Fluidmaster recommends the 

use of Flush ’n Sparkle

®

 Toilet Bowl Cleaning System (Models 

8100, 8200 or 8300). It cleans the bowl without harming tank 

parts by isolating the cleaner from the tank water, releasing it 

only to the bowl where it is needed. Cartridges supply more than 

1,000 flushes and are a snap to replace.

Remove Fill Valve from Tank

continued...

3. 

Water-Saving Feature: Hooking Up the Leak Sentry

®

 Chain

4. 

Testing Leak Sentry

®

5. 

Water-Saving Feature: Roller Clamp

6. 

Check bowl water level by flushing toilet. If bowl appears to be full but continues to 

fill, the valve may be overfilling the bowl causing excess water to siphon down the 

trapway. Adjust amount of water going down into the bowl as follows: Fill the bowl 

with a gallon of water. Wait 3 minutes until the bowl water level recedes down and 

stops. With a pencil, draw a line at the top of the water level in bowl. Now flush the 

toilet. If the valve is still filling and the water is up to the line in the bowl, then the 

amount of water going into the bowl is too high and needs to be adjusted. Adjust 

the refill by turning the roller clamp with thumb to the next lower number. Flush 

the toilet; adjust until water level in bowl is at the pencil mark when the fill valve 

shuts off. If valve shuts off and bowl is not full, adjust by turning the roller clamp 

to a higher number. Repeat until water in bowl is up to line. “O” on roller clamp 

equals no refill to bowl.

Flushing Out the Debris: Hold 

a cup over the uncapped valve 

to prevent splashing. Turn water 

supply full on and off a few 

times. Leave water supply off. 

Check for leaks. Tighten nuts 

just enough to stop leaking.

Place cap assembly on top of 

gray valve body by aligning 

cap arm and adjustment rod 

next to refill hose.

Press down on top cap rotat-

ing top & arm clockwise to 

locked position. 

Turn on water supply. 

IMPORTANT: Submerge the 

float cup under the water for 

30 seconds.

 Adjust water level 

by turning water level 

adjustment screw. To raise– 

turn clockwise; to lower – 

counterclockwise.

For your convenience, the roller clamp 
and hose clamps are pre-assembled to the 
refill hose. Attach one end of hose to refill 
clip and slide clip to right side of overflow 
pipe. Attach other end of hose to nipple on 
fill valve with a slight arching (see picture 
to the left). Cut tube if necessary. Squeeze 
tabs of hose clamp and move clamp to 
end of hose, over the fill valve nipple, then 
release tabs. Do not shove refill tube down 
overflow pipe. This will cause water loss.

FLAPPER CHAIN HOOK-UP

Lift tank lever all the way up inside tank. 

Hold tank lever there. Pull flapper chain 

tight so the flapper is lifted as high as it 

can go and attach chain to hole in lever 

directly above flapper. Make sure flapper 

chain is straight. 

Make sure flapper is closed on seat. If 

not, you may need to lengthen the flapper 

chain by a link or two to allow flapper to 

close and seal tank.

TROUBLESHOOTING

FLUSHING OUT DEBRIS

30800 Rancho Viejo Road

San Juan Capistrano, CA 92675

www.fluidmaster.com

800-631-2011

Remove cap assembly

Flush out valve

Replace cap assembly

WARRANTY

This Fluidmaster

®

 product has a limited 

warranty for a period of 5 years. For complete 

warranty details, please visit our website at 

www.fluidmaster.com

FILL VALVE WILL NOT TURN OFF.

IMPORTANT: 

Sand and rust move through 

water pipes. Always clear debris from 

water lines. Repeat steps “Removing the 

Valve Cap Assembly” & “Flushing Out the 

Debris”.

FILL VALVE WILL NOT TURN ON. 

• If float cup does not drop when flushing 

the tank: Tighten Leak Sentry

® 

chain 

by one link and then try flushing again. 

Tighten by one link at a time until valve 

turns on at flush. See “Hooking Up the 

Leak Sentry

®

 Chain”.

WATER LEVEL IN BOWL IS TOO LOW.

• Move roller clamp to higher number.

LEAK SENTRY

®

 WILL NOT LOCK FLOAT CUP.

• Make sure valve is set at 5 o’clock in tank.
• Make sure water drops below float cup 

during flush. Raise the valve higher in 

tank and reset water level.

• Device chain should be loose except 

when lever is pushed to flush tank. See 

“Hooking Up the Leak Sentry

®

 Chain”.

• Untangle Leak Sentry

®

 chain from screw 

adjustment or device area.

CAUTION:

 

Do not shove refill tube down overflow pipe.

This will cause loss of water from tank.

continued...

Removing 

the Valve Cap 

Assembly

2. 

Place shank 

washer onto 

threaded 

shank of fill 

valve. 

Flat 

side up. 

Then 

place fill valve 

in tank.

Place valve in tank; do 

not install. The Critical 

Level mark – identified 

on valve – should be 

1 inch above the top of 

the overflow pipe. This 

is a plumbing code. 

Remove fill valve from 

tank to adjust height.

Adjust height of fill valve 

by turning lower shank 

in or out of the valve 

body. 

Do not move lock 

ring

. It holds the valve 

body and shank together 

under pressure. Do not 

interchange body with 

old shank, as leaking 

can occur.    

Before installing the 

valve, remove the valve 

cap assembly. Push float 

up with right hand (see 

picture). Twist cap and 

lever counterclockwise 

1/8

th

 of a turn to unlock. 

Let cap assembly hang 

on float cup.

SHANK

WASHER

THREADED

SHANK

Simulate a leak by 

slightly lifting flapper 

chain to allow 3 or 4 

inches of water to slowly 

drain from tank. 

Fill 

valve should not turn 

on

, but remain locked 

and stay off. 

If test fails go to

 

Troubleshooting 

section. 

Make sure chain is free, 

not tangled or caught.

LEAK SENTRY

®

 CHAIN HOOK-UP

Lift tank lever all the way up inside tank and 

hold it there. Pull Leak Sentry

®

 chain until it 

lifts the float cup all the way up the fill valve 

shaft. Then connect chain & clip with no 

slack in chain to the tank lever.

NOTE: Do not cross Leak Sentry

®

 chain and 

flapper chain. If lever has only one hole, then 

attach to same hole. 

If using the

Flush ’n Sparkle

®

 

cleaning system 

the tank should 

look like this 

when setup

is complete.

Installing Fill Valve

3. 

LOCK-

NUT

CONE

WASHER

COUPLING

NUT

WATER

SHUTOFF

METAL/COPPER

FLARED TUBING

LOCK-

NUT

FLAT

WASHER

COUPLING

NUT

WATER

SHUTOFF

METAL FLANGED

TUBING

LOCK-

NUT
SPIRAL

CONE

WASHER

COUPLING

NUT

WATER

SHUTOFF

METAL SPIRAL

TUBING

LOCK-

NUT

COUPLING

NUT

WATER

SHUTOFF

VINYL/BRAIDED

CONNECTOR

PLASTIC OR METAL

COMPRESSION

BALL TUBING

CAUTION: Overtightening LOCKNUT or COUPLING

NUT could result in breakage and potential flooding.

CAUTION: DO NOT use CONE WASHER with 

PLASTIC SUPPLY LINE or METAL SPIRAL TUBING.

DO NOT use plumber’s putty to seal these fittings.

 

These parts must be used as illustrated to insure watertight connections. 

Use Fluidmaster coupling nut and 

cone washer to replace existing parts. 

Water supply tube 

must extend 1/2 inch 

inside threaded shank of valve.

Use existing coupling nut and 

existing flat washer.

Use existing spiral 

cone washer.

Do not use Fluidmaster's 

coupling nut and the cone 

washer on plastic or metal 

tubing as shown.

Captive cone washer already 

included. No additional 

washers required.

Use chart to determine the appropriate assembly parts required to properly reconnect the water supply. Do not use plumber's putty to seal these 

fittings (Teflon tape optional).

With correct washers in 

place tighten coupling 

nut. Hand-tighten only. 

CAUTION: Do not use 

Fluidmaster cone 

washer with plastic 

supply line or metal 

spiral tubing.

Place fill valve 

in tank. Align 

fill valve nipple 

to face right & 

parallel with 

back wall of 

tank. Press 

down on shank 

while tightening 

locknut. Hand- 

tighten only.

Reviews: