background image

1

Flow Control Division

Kammer Control Valves

Valves for corrosive applications

Series 132000

Index

1

Using Flowserve valves and actuators correctly

2

Transport and storage

3

Installation

4

Intended use

5

Installation

6

Pressure test pipe section

7

Normal operation and maintenance

8

Trouble-shooting

9

Product description

10

Bonnet

11

Plug and seat

12

Bellows seal

13

Stem

14

Packing

15

Test connection

16

Quick check

17

Masintenance

18

Remove actuator from valve

19

Instal actuator on valve

20

Disassemble valve

21

Assemble valve

22

Trouble-shooting chart

KMEIM3202-01 -02.04

1

U S I N G   K Ä M M E R   V A L V E S   A N D   A C T U A T O R S
CORRECTLY

1.1

Use

FLOWSERVE control valves and actuators are intended
exclusively for control of mediums in an approved
pressure and temperature range after installation in a
piping system and connection of the actuator to the
control system.

The permissible pressure and temperature limits are
defined in the operating instructions for the individual
valve series.

1.2

Terms concerning safety

The safety terms 

DANGER, WARNING, CAUTION

 and

NOTE

 are used in these instructions to highlight

particular dangers and/or to provide additional
information on aspects that may not be readily
apparent.

DANGER:

 indicates that death, severe personal injury

and/or substantial property damage will occur if proper
precautions are not taken.

WARNING:

 indicates that death, severe personal injury

and/or substantial property damage can occur if proper
precautions are not taken.

CAUTION:

indicates that minor personal injury and/or

property damage can occur if proper precautions are
not taken.

NOTE:

indicates and provides additional technical

information, which may not be very obvious even to
qualified personnel. Compliance with other, not
particularly emphasised notes, with regard to
transport, assembly, operation and maintenance and
with regard to technical documentation (e.g. in the
operating instruction, product documentation or on
the product itself) is essential, in order to avoid faults,
which in themselves might directly or indirectly cause
severe personal injury or property damage.

1.3

Safety Notes for Operator

The manufacturer is not responsible for the following
and it is therefore necessary to ensure the following
when using FLOWSERVE control valves:

1.3.1 Use valve as intended (Section 1)

DANGER:

Never operate a control valve whose

approved pressure/temperature range according to
the applicable documentation for the valve series is
not sufficient for the operating conditions. Moreover,
it must be ensured that the valve is approved for the
operating medium:

STOP!

Summary of Contents for Kammer 132000 Series

Page 1: ...t be readily apparent DANGER indicates that death severe personal injury and or substantial property damage will occur if proper precautions are not taken WARNING indicates that death severe personal...

Page 2: ...sary to ensure that the selected coating on the valve parts in contact with the medium are suitable for the mediums pressures and temperatures encountered The manufacturer is not responsible for damag...

Page 3: ...he maximum explosion limit Inside the valve the atmospheric range is not reached under the conditions see table below here Directive 95 9 EC is not applicable Please note that certain non conductive m...

Page 4: ...ipeline must be sufficient to prevent damage to any of the sealing surfaces WARNING Tighten all flange connections to the torques specified in Tables 1a or 1b When using torque wrenches ensure that th...

Page 5: ...8 TROUBLESHOOTING When troubleshooting or during general maintenance always observe Section 1 Safety precautions DANGER If a valve contaminated with dangerous substances has to be removed from the sys...

Page 6: ...1 PTFE PTFE Seat diameter mm Rangeability Seat material standard Plug material standard C v value Size DIN 15 20 25 25 40 50 80 100 Size ANSI 0 5 0 75 1 1 1 5 2 3 4 Stroke mm 10 10 10 20 20 20 40 40...

Page 7: ...the free movement of the plug stem 16 5 Check fail safe position To do this close supply pres sure and observe whether the valve opens or closes as defined 16 6 After use under varying temperatures r...

Page 8: ...es 132000 with series 2 actuator Bonnet bolt O Ring body bonnet Insert thread lock Plug Seat Body Actuator stem Packing nut Plug stem Slotted nut Test connection drawn rotated 90 Bonnet Bellows seal C...

Page 9: ...ly pres sure Manually depress the plug stem to ensure the plug is fully seated The valve plug must make contact in the valve seat i e press valve stem in all the way by hand 19 1 Screw coupling insert...

Page 10: ...Insert thread lock 5 Seat 6 Body 7 nut 8 Plug 9 Seal G1 4 only with adapter 10 Bushing 11 Bonnet 12 Screw 13 Slotted nut 14 Stem 15 Packing 16 Packing follower 17 Packing nut 18 Nut Table 6 Tightenin...

Page 11: ...the seat plug or plug stem observe the preceding instructions exactly 21 ASSEMBLE VALVE see Fig 2 21 1 Replace all worn or damaged parts Use only genuine FLOWSERVE parts Parts to be reused must be cle...

Page 12: ...20 West Sussex RH16 1TL Springville UT 84663 638824 England USA Republic of Singapore Telephone 44 0 1444 314400 Telephone 1 801 489 8611 Telephone 65 862 3332 Facsimile 44 0 144 3144401 Facsimile 1 8...

Reviews: