6.2. Pump Fault Finding
DISTINGUISHING FEATURE OF FAILURE ON DIAPHRAGM
Impression of the baffle on diaphragm
Reason: Delivery valves worn or blocked
DISTINGUISHING FEATURE OF FAILURE ON DIAPHRAGM
B
4 small impressions cause more damage on the inside, than on the outside.
Reason: Water filter blocked, or inlet valves blocked.
DISTINGUISHING FEATURE OF FAILURE ON DIAPHRAGM
C
Shear through wall of diaphragm
Reason: Pump operated whilst frozen or wear and tear after several thousand hours
A