background image

 

2

 

WATER HEATER LEO FS | ŠILDYTUVAS VANDENIU LEO FS | VODNÍ OHŘÍVAČ VZDUCHU LEO FS | VODNÁ VYKUROVACIA JEDNOTKA LEO FS 

 

EN 

LT 

Thank you for purchasing the LEO FS water heater. 
This operation manual has been issued by the FLOWAIR GŁOGOWSKI I BRZEZI

Ń

SKI SP.J. 

company.  The  manufacturer  reserves  the  right  to  make  revisions  and  changes  in  the 
operation  manual  at  any  time  and  without  notice,  and  also  to  make  changes  in  the  device 
without influencing its operation. 
 
This manual is an integral part of the device and it must be delivered to the user together with 
the device. In order to ensure correct operation of the equipment, get thoroughly acquainted 
with this manual and keep it for the future. 
 
The  devices  may  only  be  installed  and  operated  in  conditions  for  which  they  have  been 
designed. Any other application, inconsistent with this manual, may lead to the occurrence of 
accidents with dangerous consequences. Every effort must be made in order to eliminate the 
possibility  of  improper  use  of  the  device.  Access  of  unauthorised  persons  to  the  device 
should be restricted, and the operating personnel should be trained. The manufacturer bears 
no  responsibility  for  damage  resulting  from  incorrect  installation,  improper  operating,  or  not 
getting acquainted with the guidelines of the manufacturer manual.

 

D

÷

kojame už LEO FS šildytuvo vandeniu pirkim

ą

Ši

ą

  aptarnavimo  instrukcij

ą

  išleido  firma  FLOWAIR  GŁOGOWSKI  i  BRZEZI

Ń

SKI  SP.J. 

Gamintojas  palieka  sau  teis

ę

  bet  kada  ir  be  išankstinio 

į

sp

÷

jimo 

į

vesti  aptarnavimo 

instrukcijoje  pakeitimus  ir  pataisymus,  o  taip  pat  pakeitimus 

į

renginyje,  kurie  ne

į

takos  jo 

veikimo. 
 
Ši  instrukcija  tai  integralin

÷

 

į

renginio  dalis,  j

ą

  naudotojas  turi  gauti  kartu  su 

į

renginiu.  Kad 

teisingai aptarnautume 

į

rengin

į

, reikia gerai susipažinti su šia instrukcija ir saugoti j

ą

 atei

č

iai. 

 

Į

renginius  galima  montuoti  ir  eksploatuoti  tik  pagal  j

ų

  paskirt

į

.  Nesilaikant  šioje  instrukcijoje 

pateikt

ų

  nurodym

ų

,  galima  sukelti  rimtus  nelaimingus  atsitikimus, 

į

rengin

į

  eksploatuojant. 

Reikia užtikrinti, kad 

į

renginiu negalima b

ū

t

ų

 naudotis netinkamai. Negalima leisti prieiti prie 

į

renginio 

į

galiojim

ų

 neturintiems asmenims ir b

ū

tina apmokyti 

į

rengin

į

 aptarnaujant

į

 personal

ą

 

kaip  juo  naudotis.  Gamintojas  neatsako  už  jokius  pažeidimus,  atsiradusius  d

÷

l  instaliavimo 

klaid

ų

, blogo eksploatavimo arba klaid

ų

 d

÷

l gamintojo instrukcijos nurodym

ų

 nesilaikymo

 

CZ

 

SK

 

D

ě

kujeme Vám za nákup vodního oh

ř

íva

č

e LEO FS. 

Tento  návod  k obsluze  byl  vydaný  firmou  FLOWAIR  GŁOGOWSKI  I BRZEZI

Ń

SKI  SP.J. 

Výrobce si vyhrazuje právo k zavedení oprav a zm

ě

n v návodu k obsluze v libovolném 

č

ase 

a bez oznámení,  a také zm

ě

n v za

ř

ízení, které nebudou ovliv

ň

ovat jeho 

č

innost. 

 
Tento návod je integrální sou

č

ástí za

ř

ízení a musí být sou

č

ástí za

ř

ízení a spolu s ním musí 

být  uživateli  dodán.  Pro  zajišt

ě

ní  bezchybné  obsluhy  je  zapot

ř

ebí  seznámit  se  d

ů

kladn

ě

 

s tímto návodem dodán zachovat jej do budoucnosti. 

 

Za

ř

ízení  mohou  být  instalovaná  a  použita  v podmínkách,  ke  kterým  byly  p

ř

izp

ů

sobené. 

Každé  jiné  použití,  které  není  v souladu  s touto  instrukcí  m

ů

že  zp

ů

sobit  v d

ů

sledcích 

nebezpe

č

né  nehody.  Je  pot

ř

ebné  v

ě

novat  maximální  pozornost  z  d

ů

vodu  eliminování 

nesprávného  použití  za

ř

ízení.  Zamezte  p

ř

ístup k za

ř

ízení  nepovolaným  osobám  a p

ř

eškolte 

obsluhující personál. 
Výrobce  nenese  žádnou  zodpov

ě

dnost  za  poškození  a  zni

č

ení,  která  jsou  zp

ů

sobená  

chybami  v    instalaci,  nesprávným  použitím  anebo  jsou  d

ů

sledkem  neznalosti pokyn

ů

 

uvedených v návodu výrobce. 

Ď

akujeme Vám za nákup vodného ohrieva

č

a LEO FS. 

Tento  návod  k obsluhe  bol  vydaný  firmou  FLOWAIR  GŁOGOWSKI  I BRZEZI

Ń

SKI  SP.J. 

Výrobca si vyhradzuje právo na vykonanie opráv a zmien v návode k obsluhe v 

ľ

ubovo

ľ

nom 

č

ase a bez oznámení,  a tiež zmien v zariadení, ktoré nebudú ovplyv

ň

ova

ť

 jeho 

č

innos

ť

 
Tento  návod  je  integrálnou  sú

č

as

ť

ou  zariadenia  a  musí  by

ť

  sú

č

as

ť

ou  zariadenia  a  spolu 

s ním musí  by

ť

  užívate

ľ

ovi  dodaný.  Pre  zaistenie  bezchybnej  obsluhy  je  potrebné  zoznámi

ť

 

sa dôkladne s týmto návodom a zachova

ť

 ho do budúcnosti. 

 

Zariadenie  môže  by

ť

  inštalované  a  používané  výlu

č

ne  v podmienkach,  ku  ktorým  bolo 

prispôsobené.  Každé  iné  použitie,  ktoré  nie  je  v súlade  s touto  inštrukciou  môže  spôsobi

ť

 

nebezpe

č

né  nehody.  Je  potrebné  venova

ť

  maximálnu  pozornos

ť

  eliminovaniu  možnosti 

nesprávneho  použitia  zariadenia.  Zabrá

ň

te  prístupu  nepovolaných  osôb  k zariadeniu  a 

preško

ľ

te obsluhujúci personál. 

Výrobca  nenesie  žiadnu  zodpovednos

ť

  za  poškodenie  a  zni

č

enie,  ktoré  je  spôsobené 

chybami  v    inštalácii,  nesprávnou  exploatáciou  alebo    je  dôsledkom  neznalosti pokynov  
uvedených v  návode

 

výrobcu. 

Summary of Contents for LEO FS M

Page 1: ...NICAL DOCUMENTATION OPERATION MANUAL LT VANDENINIS ŠILDYTUVAS TECHNINö DOKUMENTACIJA NAUDOJIMO INSTRUKCIJA CZ VODNÍ OHŘÍVAČ VZDUCHU TECHNICKÁ DOKUMENTACE NÁVOD NA OBSLUHU SK VODNÁ VYKUROVACIA JEDNOTKA TECHNICKÁ DOKUMENTÁCIA NÁVOD NA OBSLUHU ...

Page 2: ...ei PT 1000 PAJUNGIMAS 34 PT 1000 DAVIKLIO PAJUNGIMAS 38 9 PALEIDIMAS IR EKSPLOATAVIMAS 40 10 SERVISINIS APTARNAVIMAS 41 CZ SK 1 RADY A NEVYHNUTNÁ BEZPEČNOSTNÍ OPATŘENÍ 3 2 VŠEOBECNÉ INFORMACE 4 3 KONSTRUKCE A HLAVNÍ ROZMĚRY 5 4 TECHNICKÁ DATA 7 5 TABULKY OHŘÍVACÍCH VÝKONŮ LEO FS S 8 6 TABULKY OHŘÍVACÍCH VÝKONŮ LEO FS M 13 7 MONTÁŽ 19 8 MĚŘENÍ A REGULACE 20 8 1 ČÁSTI MĚŘENÍ A REGULACE LEO FS 21 8 2...

Page 3: ... aptarnaujantį personalą kaip juo naudotis Gamintojas neatsako už jokius pažeidimus atsiradusius d l instaliavimo klaidų blogo eksploatavimo arba klaidų d l gamintojo instrukcijos nurodymų nesilaikymo CZ SK Děkujeme Vám za nákup vodního ohřívače LEO FS Tento návod k obsluze byl vydaný firmou FLOWAIR GŁOGOWSKI I BRZEZIŃSKI SP J Výrobce si vyhrazuje právo k zavedení oprav a změn v návodu k obsluze v...

Page 4: ...e vandenį paduodančių elementų paleidžiant taisant bei prižiūrint šildymo aparatus reikia laikytis visuotinai pripažintų taisyklių ir saugumo standartų CZ SK Před vykonáním jakýchkoliv činností je potřebné se seznámit s tímto návodem k obsluze Zařízení může být instalované pouze kvalifikovaným personálem který vlastní odpovídající oprávnění a kvalifikace V průběhu vykonávání práce se zařízením je ...

Page 5: ...i ypač tinka barams restoranams diskotekoms automobilių ar baldų salonams LEO FS šildytuvai skirti montuoti patalpose CZ SK Vytápěcí zařízení LEO FS tvoří decentralizovaný systém vytápění Jsou vhodné na vyhřívání malých a středně velkých objektů Jsou napojená na vytápěcí vodu která odevzdáváním tepla prostřednictvím výměníku tepla zahřívá vzduch Moderní vzhled kryt který schovává všechny elektrick...

Page 6: ...erodinamiškas purkštukas paskirsto orą visame šilumokaičio paviršiuje D l to šilumokaitis naudojamas pačiu optimaliausiu būdu Purkštuko forma leidžia geriau reguliuoti oro srautą mažina triukšmą srauto pasipriešinimą D l to bereikalingai prarandama mažiau šilumos Purkštukas pagamintas iš ABS plastiko Vzduchová tryska Díky použití speciálně tvarované aerodynamické trysky proud vzduchu vyfukovaný ve...

Page 7: ...ojamos ment s keičia oro pūtimo kryptį Kreiptuvus galima nustatyti į vertikalią arba horizontalią pad tį Oro ment s pagamintos iš anodinto aliuminio ir puošia šildytuvą Usměrňovací vzduchové lamely Ovládané manuálně umožňují změnu sklonu vyfukovaného vzduchu Vyrobené z anodizovaného hliníku zaručují estetický vzhled Usmerňovacie vzduchové lamely Ovládané manuálne umožňujú zmenu sklonu vyfukovaného...

Page 8: ...sugerties koeficiento patalpai 1500m talpos 5m atstumo nuo įrenginio Izoterminio srauto diapazono lygis kritiniu greičiu 0 5m s LEO FS S M Napětí 230V 50Hz Odběr proudu 0 4A 0 25A Příkon 92W 57 5W IP 54 Izolační třída F Úroveň akustického tlaku 45dB A Max teplota vytápěcí vody 95o C Max pracovní tlak 1 6MPa Připojovací závitové spoje Hmotnost zařízení 13 8kg Hmotnost zařízení naplněného vodou 15kg...

Page 9: ... 3 5 3 0 264 0 8 30 1 5 2 2 190 0 5 20 9 0 2 6 113 0 2 31 1 0 2 7 231 0 6 31 9 0 1 9 161 0 3 22 3 5 2 3 99 0 1 33 0 5 2 3 197 0 5 32 7 5 1 6 135 0 2 24 0 10 2 0 86 0 1 34 6 10 1 9 162 0 3 33 2 10 1 3 109 0 2 25 7 15 1 7 74 0 1 36 4 15 1 5 133 0 2 34 4 15 1 0 84 0 1 27 3 20 1 4 61 0 1 38 0 20 1 2 108 0 2 36 0 20 0 7 60 0 1 29 0 EN LT Efficiency of LEO FS S with a speed regulator TR in 1 step V airf...

Page 10: ... 3 5 4 4 381 1 5 27 2 5 3 3 284 0 9 19 0 0 3 6 159 0 3 27 2 0 3 8 334 1 2 28 7 0 2 7 235 0 7 20 2 5 3 0 132 0 2 28 1 5 3 3 288 0 9 30 2 5 2 1 180 0 4 20 8 10 2 6 115 0 2 30 4 10 2 8 242 0 7 31 5 1 3 1 7 146 0 3 23 0 15 2 2 98 0 1 32 6 15 2 2 195 0 4 32 6 15 1 3 112 0 2 25 2 20 1 9 81 0 1 34 8 20 1 7 145 0 3 33 3 20 0 9 80 0 1 27 4 EN LT Efficiency of LEO FS S with a speed regulator TR in 2 step V ...

Page 11: ...23 8 5 5 7 494 2 3 24 1 5 4 3 371 1 5 17 0 0 4 9 213 0 5 25 5 0 5 0 434 1 9 26 1 0 3 6 310 1 1 18 7 5 4 1 179 0 4 26 9 5 4 3 375 1 4 27 9 5 2 9 248 0 7 20 2 10 3 2 140 0 3 27 3 10 3 6 317 1 1 29 7 10 2 1 178 0 4 21 1 15 2 7 118 0 2 29 9 15 3 0 258 0 7 31 3 15 1 6 136 0 3 23 7 20 2 2 98 0 1 32 5 20 2 3 197 0 5 32 7 20 1 1 96 0 1 26 2 EN LT Efficiency of LEO FS S with a speed regulator TR in 3 step ...

Page 12: ...19 2 5 6 4 550 3 0 13 4 0 7 3 320 1 0 21 6 0 7 4 641 3 8 21 7 0 5 4 464 2 2 15 7 5 6 3 275 0 8 23 9 5 6 4 555 2 9 24 1 5 4 4 377 1 5 18 0 10 5 3 229 0 6 26 0 10 5 4 471 2 2 26 5 10 3 3 288 0 9 20 1 15 4 1 179 0 4 27 7 15 4 4 387 1 5 28 8 15 2 1 179 0 4 21 4 20 2 9 127 0 2 29 2 20 3 5 302 1 0 30 9 20 1 4 125 0 2 24 5 EN LT Efficiency of LEO FS S with a speed regulator TR in 4 step V airflow PT heat...

Page 13: ...12 3 1073 9 6 14 1 5 9 4 812 6 0 9 5 0 10 9 473 2 1 17 2 0 10 9 945 7 6 17 2 0 7 9 686 4 4 12 5 5 9 4 409 1 6 20 1 5 9 4 820 5 9 20 2 5 6 5 561 3 1 15 4 10 7 9 345 1 2 23 0 10 8 0 696 4 4 23 1 10 5 0 436 2 0 18 2 15 6 4 280 0 8 25 7 15 6 6 573 3 1 26 0 15 3 5 306 1 0 20 9 20 4 8 210 0 5 28 1 20 5 2 452 2 0 28 8 20 1 2 158 0 3 23 1 EN LT Efficiency of LEO FS S with a speed regulator TR in 5 step V ...

Page 14: ... 5 9 259 0 7 23 8 0 6 0 522 2 6 24 0 0 4 3 376 1 5 17 4 5 5 1 221 0 5 25 7 5 5 2 451 2 0 26 2 5 3 5 303 1 0 19 3 10 4 1 180 0 4 27 2 10 4 4 382 1 5 28 2 10 2 6 226 0 6 20 8 15 3 1 135 0 2 28 0 15 3 6 313 1 0 30 2 15 1 8 155 0 3 22 6 20 2 5 111 0 2 30 9 20 2 8 242 0 7 32 0 20 1 3 109 0 2 25 4 EN LT Efficiency of LEO FS M with VNT20 VNTLCD controller set on 20 V airflow PT heat capacity Tp1 inlet ai...

Page 15: ...3 4 12 6 0 7 9 346 1 2 20 7 0 8 0 693 4 3 20 8 0 5 8 502 2 5 15 1 5 6 8 298 0 9 23 2 5 6 9 600 3 3 23 3 5 4 7 409 1 7 17 5 10 5 7 249 0 7 25 4 10 5 9 509 2 5 25 8 10 3 6 314 1 1 19 8 15 4 5 197 0 4 27 3 15 4 8 418 1 7 28 2 15 2 3 203 0 5 21 4 20 3 1 133 0 2 28 6 20 3 8 328 1 1 30 5 20 1 5 131 0 2 24 2 EN LT Efficiency of LEO FS M with VNT20 VNTLCD controller set on 40 V airflow PT heat capacity Tp...

Page 16: ... 701 4 6 11 0 0 9 4 409 1 6 18 9 0 9 4 816 5 8 18 9 0 6 8 592 3 4 13 7 5 8 1 353 1 3 21 6 5 8 1 708 4 5 21 7 5 5 6 484 2 4 16 4 10 6 8 296 0 9 24 2 10 6 9 600 3 3 24 4 10 4 3 374 1 5 19 0 15 5 5 238 0 6 26 6 15 5 7 494 2 3 27 0 15 3 0 257 0 8 21 3 20 3 9 171 0 4 28 5 20 4 5 388 1 5 29 6 20 1 7 145 0 3 23 6 EN LT Efficiency of LEO FS M with VNT20 VNTLCD controller set on 60 V airflow PT heat capaci...

Page 17: ... 9 0 777 5 5 10 0 0 10 4 453 2 0 17 7 0 10 4 904 7 0 17 7 0 7 6 656 4 1 12 9 5 9 0 391 1 5 20 6 5 9 0 784 5 4 20 6 5 6 2 537 2 8 15 7 10 7 6 329 1 1 23 3 10 7 7 665 4 0 23 5 10 4 8 417 1 8 18 5 15 6 1 267 0 8 26 0 15 6 3 548 2 8 26 3 15 3 4 291 1 0 21 0 20 4 5 198 0 5 28 3 20 5 0 431 1 8 29 0 20 1 8 154 0 3 23 2 EN LT Efficiency of LEO FS M with VNT20 VNTLCD controller set on 80 V airflow PT heat ...

Page 18: ... 9 4 812 6 0 9 5 0 10 9 473 2 1 17 2 0 10 9 945 7 6 17 2 0 7 9 686 4 4 12 5 5 9 4 409 1 6 20 1 5 9 4 820 5 9 20 2 5 6 5 561 3 1 15 4 10 7 9 345 1 2 23 0 10 8 0 696 4 4 23 1 10 5 0 436 2 0 18 2 15 6 4 280 0 8 25 7 15 6 6 573 3 1 26 0 15 3 5 306 1 0 20 9 20 4 8 210 0 5 28 1 20 5 2 452 2 0 28 8 20 1 2 158 0 3 23 1 EN LT Efficiency of LEO FS M with VNT20 VNTLCD controller set on 100 V airflow PT heat ...

Page 19: ...he nuts Make electrical water and automatics connections 4 Set up the casing and fasten in with 4 screws 2 in the upper and 2 in the lower part of the appliance D l naudojamo specialaus r mo LEO FS šildytuvui nereikia jokių papildomų laikiklių montuojant jį ant sienos LEO FS šildytuvą galima montuoti ant sienos Nerekomenduojama montuoti šildytuvo po lubomis Montuojant reikia palikti minimalius tar...

Page 20: ...omatickou instalaci 4 Přiložte kryt a připevněte ho 4 šrouby 2 v horní a 2 v dolní části zařízení Vďaka použitiu špeciálnej nosnej konštrukcie sa na upevnenie ohrievača LEO FS na stenu nepoužívajú žiadne ďalšie montážne držadlá Ohrievač LEO FS je určený pre montáž na stenu Neodporúča sa upevňovať ho pod strop Pri montáži je potrebné dodržať minimálne vzdialenosti od vodorovných a zvislých prepážok...

Page 21: ...ohoto typu mají ventilátory s elektronicky komutovaným motorem EC a díky tomu nejsou potřebné doplňkové regulátory To umožňuje práci zařízení v poloze AUTO výkon zařízení se plynule mění v závislosti od potřeby tepla v místnosti Stejně je možné použít jeden regulátor na ovládání maximálně 10 zařízení Typ S ohřívač pracuje v poloze ON OFF Na ovládání výkonnosti ventilátoru se používají regulátory r...

Page 22: ...t inductive 2A resistivity 5A Programuojamas patalpos termostatas Temperatūros nustatymo diapazonas 5 280 C kas 0 50 C Temperatūros darbo diapazonas 0 500 C Apsaugos lygis IP30 Maitinimas 2x1 5V AA baterijos elementai Vožtuvo kontaktų apkrova indukcin 2A atsparumo 5A Prostorový termostat s programovatelným kalendářem Rozsah nastavení teploty 5 28o C po 0 5o C Rozsah pracovní teploty 0 50o C Stupeň...

Page 23: ...tnost TR 1 5kg TRd 2 5kg Proud TR 1 5A TRd 3 0A 5 stupňový transformátorový regulátor otáčok Napájacie napätie 230V 50 60Hz Stupeň ochrany IP54 Rozsah pracovnej teploty 0 40o C Regulačné stupne 1 2 3 4 5 Ur V Ir A TR 115 1 5 135 1 5 155 1 5 180 1 5 230 1 5 TRd 70 1 5 85 1 8 105 2 2 145 2 7 230 3 0 Hmotnosť TR 1 5kg TRd 2 5kg Prúd TR 1 5A TRd 3 0A DSS2d Stepless fan speed regulator Supply voltage 2...

Page 24: ... 100 Rozsah pracovnej teploty 10 60o C Čidlo teploty vnútorné vn PT 1000 Stupeň ochrany IP20 Prípustná záťaž kontaktov ventilu induk 3A resist 8A VNTLC D Programmable fan speed controller with a built in room thermostat Supply voltage 230V 50Hz Output control signal analogue 0 10V Temperature adjustment range 5 35 o C Method of speed regulation Manual control LCD display Speed regulation range 0 1...

Page 25: ...chrany IP 20 Stupeň ochrany IP 20 Rozsah pracovnej teploty 20 70 o C PT 1000 IP65 Wall mounted temperature sensor Protection degree IP65 Operation temperature range 50 110 o C Sieninis temperatūros matavimo daviklis Apsaugos lygis IP65 Darbo temperatūros diapazonas 50 110 o C Vnější čidlo teploty s třídou ochrany IP 65 Stupeň ochrany IP 65 Rozsah pracovní teploty 50 110 o C Vonkajší snímač teploty...

Page 26: ...ikos sistema ventiliatoriaus pajungimo kabelin mova maitinimo šaltinio OMY 3x1mm 2 prijungimas RA RD termostatas maitinimas skirstomoji d ž skyriklis U1 m lynas faz U2 juodas nulis Z rudas PE žaliai geltonas įžeminimas CZ SK Práci ventilátoru ovládá termostat do místnosti RA anebo RD prostřednictvím zastavování a spouštění motoru ventilátoru Parametry ohřívací vody jsou kontrolované systémem autom...

Page 27: ...jungimo kabelin mova maitinimo šaltinio OMY 3x1mm2 prijungimas RA RD termostatas prijungimas OMY 2x0 5mm2 maitinimas skirstomoji d ž skyriklis 230V 50Hz vožtuvas su SRS servovarikliu U1 m lynas faz U2 juodas nulis Z rudas PE žaliai geltonas įžeminimas CZ SK Systém s termostatem do místností RA anebo RD a ventilem se servomotorem SRS Termostat ovládá práci ventilu zavíráním a otevíráním průtoku ohř...

Page 28: ...m2 prijungimas RA RD termostatas prijungimas OMY 2x0 5mm2 maitinimas skirstomoji d ž skyriklis 230V 50Hz vožtuvas su SRS servovarikliu TR TRd sukimosi greičio reguliatorius maitinimo šaltinio OMY 3x1mm2 prijungimas U1 m lynas faz U2 juodas nulis Z rudas PE žaliai geltonas įžeminimas CZ SK Systém ovládání který tvoří termostat do místností RA anebo RD ventil se servomotorem SRS a transformátorový r...

Page 29: ...yriklis 230V 50Hz vožtuvas su SRS servovarikliu DSS2d sukimosi greičio reguliatorius maitinimo šaltinio OMY 3x1mm2 prijungimas U1 m lynas faz U2 juodas nulis Z rudas PE žaliai geltonas įžeminimas TK šilumin apsauga termokontaktas Nepanaudota turi būti uždara CZ SK Systém ovládání který tvoří termostat do místností RA anebo RD ventil se servomotorem SRS a napěťový regulátor otáček ventilátoru DSS2d...

Page 30: ...s režimas P3 ventiliatoriaus minimalaus greičio nustatymas darbui AUTO režime Gamyklinis nustatymas 30 sukimosi greičio reguliavimas temperatūros nustatymas bud jimas CZ SK SW3 přepínač pracovního režimu AUTO MANUAL 1 režim práce manual 2 režim práce auto Tovární nastavení 1 SW2 volba čidla teploty 1 vnitřní čidlo 2 vnější čidlo Tovární nastavení 1 SW1 volba režimu práce ventilátoru 1 režim termos...

Page 31: ...distributor simultaneous operation of up to 10 devices NOTE In order to increase the general safety the fan connection is executed in the junction box located outside on the cable Valdymo sistemą sudaro šie elementai VNT20 valdymo panelis bei kaip opcija vožtuvas su SRS servovarikliu o taip pat PT 1000 IP20 abra PT 1000 IP65 iš kabelio išvesta ventiliatoriaus pajungimo kabelin mova maitinimo šalti...

Page 32: ...ROL LEO FS M VALDYMAS VNT20 SRS and PT 1000 connection VNT20 SRS PT 1000 pajungimas VNT20 connection diagram VNT20 pajungimo schema VNT20 connection diagram for several heaters VNT20 pajungimo prie keleto šildytuvų schema ...

Page 33: ...ařízení POZOR Pro zvýšení celkové bezpečnosti připojení ventilátoru se provádí v instalační krabici která je vyvedená na kabelu Elementmi ovládania sú ovládací panel VNT20 a voliteľne ventil so servomotorom SRS a vonkajšie čidlo PT 1000 IP20 alebo PT 1000 IP65 inštalačná skrinka ventilátora vyvedená na kábli napájanie OMY 3x1mm2 riadenie LIYCY 2x0 5mm2 tienený ventil SRS pripoj OMY 2x0 5mm2 ovláda...

Page 34: ...S M OVLÁDANIE LEO FS M Připojení VNT 20 SRS a PT 1000 Pripojenie VNT20 SRS a PT 1000 Schéma připojení VNT20 Schéma pripojenia VNT20 Schéma připojení VNT20 k několika ohřívačům Schéma pripojenia VNT20 k niekoľkým ohrievačom ...

Page 35: ...on of the VNTLCD controller is included in the operation manual attached to it NOTE In order to increase the general safety the fan connection is executed in the junction box located outside on the cable Valdymo sistemą sudaro šie elementai valdymo panelis su VNTLCD ekranu bei kaip opcija vožtuvas su SRS servovarikliu bei PT 1000 išorinis daviklis iš kabelio išvesta ventiliatoriaus pajungimo kabel...

Page 36: ...EO FS M VALDYMAS VNTLCD SRS and PT 1000 Connection VNTLCD SRS bei PT 1000 pajungimas VNTLCD connection diagram VNTLCD pajungimo schema VNTLCD connection diagram for several heaters VNTLCD pajungimo prie keleto šildytuvų schema ...

Page 37: ...u k obsluze POZOR Pro zvýšení celkové bezpečnosti se připojení ventilátoru provádí v instalační krabici která je vyvedena na kabelu Elementmi ovládania sú ovládací panel s displejom VNTLCD a voliteľne ventil so servomotorom SRS a vonkajšie čidlo PT 1000 inštalačná skrinka ventilátora vyvedená na kábli napájanie OMY 3x1mm 2 riadenie LIYCY 2x0 5mm 2 tienený ventil SRS pripoj OMY 2x0 5mm 2 ovládač VN...

Page 38: ...FS M OVLÁDANIE LEO FS M Připojení VNTLCD SRS a PT 1000 Pripojenie VNTLCD SRS a PT 1000 Schéma připojení VNT20 Schéma připojení VNT20 Schéma připojení VNT20 k několika ohřívačům Schéma připojení VNT20 k niekoľkým ohrievačom ...

Page 39: ... 1000 daviklius Paveiksl lyje yra pateikta 4 daviklių pajungimo schema D mesio Negalima jungti prie valdiklių kito PT 1000 daviklių skaičiaus nei yra nurodyta Maksimalus daviklio montavimo atstumas nuo tvarkykl s 50m CZ SK Do ovladačů VNT20 a VNTLCD je možné současně připojit 1 nebo 4 čidla PT 1000 Schéma připojení 4 čidel bylo představené na obrázku POZOR Není dovolené připojení jiného počtu čide...

Page 40: ...nium lamellas For the time of performing inspection or cleaning the device the electrical power supply should absolutely be disconnected In the case if water is drained from the device for a longer period of time the exchanger tubes should additionally be blown through with compressed air Nurodymai instaliacijai pajungti Jungti reikia taip kad sujungimuose nebūtų įtampos Aukščiausiame instaliacijo...

Page 41: ...e zařízení vypuštěná na delší dobu je potřebné dodatečně zprůchodnit trubky výměníku stlačeným vzduchem Pokyny týkajúce sa inštalácie Pripojenie by malo byť prevedené spôsobom ktoré vylučuje možnosť vzniku napätia Odporúča sa použiť odvzdušňovacie ventily v najvyššom bode inštalácie Inštalácia by mala byť prevedená tak aby sa v prípade poruchy dal prístroj rozobrať V takom prípade je najlepšie pou...

Page 42: ...ŁOGOWSKI I BRZEZIŃSKI SP J ul Chwaszczyńska 133A 81 571 Gdynia tel 48 58 669 82 20 fax 48 58 627 57 21 e mail info flowair pl www flowair com CZ SK V případě jakýchkoliv závad v činnosti zařízení prosíme o kontakt se servisním oddělením výrobce Za exploataci zařízení způsobem který není v souladu s jeho určením osobami k tomu neoprávněnými a za škody vzniklé z tohoto titulu výrobce nezodpovídá Vyr...

Page 43: ...42 NOTES UŽRAŠAI POZNÁMKY POZNÁMKY ...

Page 44: ...43 LEO FS 1 0 08 09 ENLTCZSK ...

Reviews: