SB-0259 Rev A Status: PRODUCTION
1 of 10
2011 Flow International Corporation
UNCONTROLLED COPY
PRINTED 7/29/11
SB-0259
Installing the HyPlex® Prime
Major Maintenance Kit
Introduction
Use the procedure in this service bulletin when installing the Major Maintenance Kit on your HyPlex
Prime pump. This service is performed at every fourth required maintenance interval for the life of the
equipment. The complete major maintenance kit schedule is listed in your FLOW service manual.
Tools
You will need the following tools:
Pressure loading tool (049512-1)
Combination wrenches (14 mm to 32 mm)
½ in. drive socket set (14 mm to 32 mm)
½ in. torque wrench (10 to 200 ft-lb)
Note:
You may need two torque wrenches.
Feeler gauge set
Screwdriver set
Snap-ring pliers
0-1 in. micrometer or dial caliper
3/8 in. hex bit
½ in. hex bit
Repair kit
Major maintenance kit, 050624-2
CAUTION
Failure to follow these step-by-step instructions and the procedures in your FLOW
service manual could result in premature failure or damage to the equipment.
Note
: All components should be clean and free of debris prior to assembly. Keeping the work area clean
is important while working on the equipment.