Flomatic Split Disc 895 Installation Instructions Download Page 1

 

 Split Disc® Check Valves    Wafer Style Installation 

Instructions 

895 2” thru 24” 

Flomatic Corporation

 

Flomatic Corp, 15 Pruyn’s Island, Glens Falls, New York 12801 

Phone: 518-761-9797           Fax: 518-761-9798        www.flomatic.com 

895 

Rev. A (11/16) 

 

 
Operation: 

 

Flomatic 895 Split Disc® check valves are normally installed downstream of a pump.  Upon pump shut down 
the torsion spring closes the discs before the water reverses flow.  This will prevent flow reversal slam, which 
helps to eliminate water hammer and system surges associated with valve closure.  On start-up, the water 
forces the discs open and allows water to pass thru the valve.  The only moving parts are the discs and 
spring, which are guided in the valve body by the hinge pin and stop pin to prevent the disc from slamming 
together. 

 

Installation: 

 

Installation must be performed by qualified, licensed personnel only. 
Remove all packing materials from the valve, this includes anything that keeps the valve from being 
damaged during shipping. 

 

The Flomatic 895 Split Disc® check valve can be installed vertically (flow up only) or horizontally. 

NOTE

:  

When installing the horizontally it MUST be installed with the disc hinge pin (4) and stop pin 

(5) in the vertical position (see diagram on next page)

.  The valve must be installed with the flow arrow on 

the tag pointing in the direction of flow when the system is in operation.  Three diameters of straight pipe 
upstream of the valve are recommended to prevent turbulent flow thru the valve, which will cause vibration 
and wear.  Valves must be mounted between ANSI B16.5 flat face flanges with 1/16 min thickness ring 
gaskets.  Centering the valve properly is important to prevent damage to the valve and/or leakage.  Never lift 
the valve by the discs.  Hand tighten, then torque the bolts using the cross-over flange bolt tightening method.  
This will load the bolts evenly and help eliminate concentrated stresses.  When using in series with a butterfly 
valve it must be installed at 

least

 one pipe diameter downstream of the Split Disc® due to the fact that the 

disc extend beyond the valve body. 

 

Valve Size (in) 

Bolt Diameter (in) 

Bolt Torque 

(ft/lbs) 

Valve Size (in) 

Bolt Diameter (in) 

Bolt Torque 

(ft/lbs) 

5/8 

25-75 

10 

7/8 

60-180 

2.5 5/8 

25-75 12  7/8 

65-200 

5/8 

25-75 

14 

80-250 

4  3/4 

 25-75 16 

1 90-300 

3/4 

40-120 

18 

1-1/8 

100-350 

6 3/4 

40-120 

20 

1-1/8 

120-450 

3/4 

50-150 

24 

1-1/4 

150-500 

 

Maintenance: 

 

The Flomatic 895 Spilt Disc® check valve should be inspected yearly for damage or leakage by a qualified 
and licensed person only.  Leakage can be checked for by listening for noise when the pump is shut down.  If 
there is visible damage or leakage to the valve or internal leakage sounds isolate the valve, relieve the 
pressure, drain the water from the line and remove the valve.  If the resilient seat is damaged the valve must 
be replaced. 

 

Disassembly / Reassembly: 

 

The Flomatic 895 Spilt Disc® check valve can be disassembled by removing the hinge pin retainer (7).  Next 
drive out the disc hinge pin (4) with a small rod bar while holding the torsion spring (3) down to keep it in 
place.  Lift the discs (2) and bearings (6) from the valve.  Inspect the disc (2) the pins (4&5), bearings (6) and 
valve body for signs of wear or damage.  Replace parts as needed.  If the valve seat is damaged the valve 
must be replaced as this will cause leakage. 
 