FLIR VP50-2 User Manual Download Page 1

USER MANUAL
Non-Contact
Voltage De
Flashlight

VP50–2 (110V regions) and VP52–2 (220V regions)

Summary of Contents for VP50-2

Page 1: ...USER MANUAL Non Contact Voltage Detector Flashlight VP50 2 110V regions and VP52 2 220V regions...

Page 2: ......

Page 3: ...USER MANUAL Non Contact Voltage Detector Flashlight NAS100038 r AD 64642 64642 en US iii...

Page 4: ......

Page 5: ...ct Description 6 5 2 Button Indicator and Beeper Descriptions 6 6 Operation 8 6 1 Low normal and High Sensitivity Modes 8 6 2 Basic Operation 8 6 3 Flashlight 9 6 4 Low Battery Indication 9 6 5 Auto P...

Page 6: ......

Page 7: ...the property of their respective owners 1 2 Quality Assurance The Quality Management System under which these products are developed and manufactured has been certified in accordance with the ISO 900...

Page 8: ...is its normal or low sensitivity mode The VP52 2 220 V re gions has a minimum excitation voltage of 190 V AC this is its normal or low sensitivity mode Both models have a high sensitivity mode allowin...

Page 9: ...color LED alarm indicators Bright flashlight Dual LED illuminator at probe tip ON OFF button with auto power off APO CAT IV 1000 V safety rated Low battery indication status LED flashing amber Robust...

Page 10: ...om the voltage source or if the tested frequency is outside of the specified range Do not attempt to detect voltages outside the specified range CAUTION Use caution with voltages 30 V AC If the device...

Page 11: ...ollow all safety information warnings and cautions before attempting to operate this device Failure to do so can result in death or serious injury Risk of electrical shock exists under normal use Doub...

Page 12: ...nt access cap 9 Flashlight 5 2 Button Indicator and Beeper Descriptions Power button Short press to switch the meter ON Long Press to switch OFF When meter is powered short press to toggle high and lo...

Page 13: ...igh sensitivity mode If the status indicator is flashing amber please replace the batteries If the status indicator is flashing red the meter is malfunctioning please return the meter for service BEEP...

Page 14: ...ormal low sensitivity mode the status indicator illuminates solid green In high sensitivity mode the status indicator illuminates solid amber The VP50 2 is intended for 110 V AC regions and the VP52 2...

Page 15: ...rm indicator flashes red With voltage detected in high sensitivity mode the alarm indicator flashes amber 6 To switch OFF long press the power button The meter beeps once and the status indicator and...

Page 16: ...Battery Replacement 1 Switch the meter OFF before replacing the batteries 2 Unscrew the cap as shown 3 Replace the 2 x AAA batteries observing correct polarity as shown on the outside of the case near...

Page 17: ...y rating CAT IV 1000 V Frequency range 45 65 Hz Operating temperature 14 122 10 50 Storage temperature 4 140 20 60 Dimensions 6 24 x 1 02 x 1 14 in 158 5 x 26 x 29 mm Weight 2 1 oz 59 g including batt...

Page 18: ...er Support 9 Repair Calibration and Technical Support https support flir com 9 1 Corporate Headquarters FLIR Systems Inc 27700 SW Parkway Avenue Wilsonville OR 97070 USA NAS100038 r AD 64642 64642 en...

Page 19: ...Three Year Warranty 10 This product is protected by FLIR s 3 Year Limited Warranty Visit https support flir com prodreg to read the 3 Year Limited Warranty document NAS100038 r AD 64642 64642 en US 13...

Page 20: ...NAS100038 r AD 64642 64642 en US 14...

Page 21: ......

Page 22: ...support flir com Copyright 2020 FLIR Systems Inc All rights reserved worldwide Disclaimer Specifications subject to change without further notice Models and accessories subject to regional market con...

Reviews: