Problem
Action
Defect of image (mosaic)
in corners
Bad quality of NUC or search criteria of Bad
pixels too severe. Remake NUC and BPR.
The problem is solved?
No
Contact FLIR Systems After Sales Service
Strongly
concentric
image
Do a 1 point NUC to eliminate the Narcissus
effect due to the filter. The problem is solved?
Yes
The emissivity of the filmed object is too
low (< 0,75). To give angle with the object with
respect to the camera to remove a Narcissus
effect (the detector is seen by reflection on the
object)
And/or paint the object filmed with a coat of
very good emissivity paint
The image shows bubbles
or honey comb structure
The detector had been exposed to strong visible
light. Store the camera in its case with the lens
cover until the pattern disappear. It can take
from a couple of hour to up to few days,
depending on the exposition.
The problem is solved?
No
Contact FLIR Systems After Sales Service
9.2.
How to contact after sales service?
Before contacting the after sales service or your representative, note the serial
number located on the camera. A FLIR Systems engineer will discuss the
procedure with you.
FLIR Systems after sales service is reachable at the address: