Value
Label
■
Select
Off
to disable the alarm
■
Select
Above
to assign an alarm color to all
pixels above the alarm temperature
■
Select
Below
to assign an alarm color to all
pixels below the alarm temperature
■
Off
■
Above
■
Below
Alarm
■
Select
Color only
to assign only a color to the
pixels when an alarm is triggered.
■
Select
Silent
to additionally make the font of
the temperature result increase in size and be
displayed against a red background (
i.e.
a visu-
al alarm)
■
Select
Beep
to additionally make the camera
trigger a beep when an alarm is triggered.
■
Color only
■
Silent
■
Beep
Alarm output
Enter an delta alarm value by pressing the naviga-
tion pad left/right.
➲
This label is only available if
Update ref temp
has been previously selected in the
Settings
dialog
box.
N/A
Delta alarm
For information purposes only.
The reference temperature is calculated and updat-
ed ’on the fly’.
➲
This label is only available if
Update ref temp
has been previously selected in the
Settings
dialog
box.
User-defined
Ref temp
Enter a temperature value by pressing the naviga-
tion pad left/right.
User-defined
Alarm temp
10.4.3
Manual adjust/Automatic adjust
Point to
Manual adjust
and press MENU/YES to manually select
level
and
span
set-
tings. The level command can be regarded as the
brightness
, while the span command
can be regarded as the
contrast
.
■
Press the navigation pad up/down to change the level (indicated by an arrow
pointing upwards or downwards in the temperature scale)
■
Press the navigation pad left/right to change the span (indicated by two arrows
pointing away from each other or towards each other)