PREINSTALLATION CHECKLIST -  ALL INSTALLATIONS

 

SW0880

1018

Supersedes

0214

INSTALLATION INSTRUCTIONS

DO NOT USE FOR PUMPING OILS, GASOLINE OR ANY PETROLEUM BY-PRODUCTS.

Notice to Installer:  Instructions must remain with installation.

95 N. Oak St. • Kendallville, IN 46755 • 1-800-345-9422

1.    Inspect your pump.

 Occasionally, products are damaged during shipment. If the unit is damaged, contact your dealer 

before using. 

2.    Carefully read the literature

 provided to familiarize yourself with specific details regarding installation and use. These 

materials should be retained for future reference.

1.

   

 Make sure there is a properly installed ground 

fault circuit interrupter (GFCI) protected circuit available.  All 

pumps are furnished with provisions for proper grounding to 

help protect you against the possibility of electrical shock.

2.  

 

 Make certain that the ground fault receptacle 

is within the reach of the pump’s power supply cord 

DO 

NOT USE AN EXTENSION CORD.

  Extension cords that 

are too long or too light do not deliver sufficient voltage to 

the pump motor.  But, more important, they could present a 

safety hazard if the insulation were to become damaged or 

the connection ends were to fall into the sump and become 

wet.

3.   

 

Make sure the pump electrical supply cir-

cuit is equipped with fuses or circuit breakers of proper 

capacity.

  A separate branch circuit is recommended, sized 

according the National Electrical Code for the current shown 

on the pump name plate.

4.   

 

TESTING FOR GROUND.

 As a safety measure, 

each electrical outlet should be checked for ground using 

an Underwriters Laboratory Listed circuit analyzer which will 

indicate if the power, neutral and ground wires are correctly 

connected to your outlet. If they are not, call a qualified 

licensed electrician.

5.

 

 Installation and checking of electrical circuits 

and hardware should only be performed by a qualified licensed 

electrician.

6.

 

 FOR YOUR PROTECTION, ALWAYS DIS-

CONNECT PUMP FROM ITS POWER SOURCE BEFORE 

HANDLING.

7.

 

 These pumps are supplied with a 3-prong 

grounded plug to help protect you against the possibility of 

electrical shock.  

DO NOT UNDER ANY CIRCUMSTANCES 

REMOVE THE GROUND PIN.

  The 3-prong plug 

must 

be 

inserted in a mating 3-prong fault interrupter receptacle.  

If 

the installation does not have such a receptacle, it must be 

changed to the proper type, wired, and grounded in accor-

dance with the National Electrical Code and all applicable 

local codes and ordinances.

1.

    

 Check to be sure your power source is ca-

pable of handling the voltage requirements of the motor, 

as indicated on the pump name plate. 

2. 

 The installation of automatic pumps with 

auxiliary float switches is the responsibility of the installing 

party and care should be taken that the tethered float 

switch will not hang up on the pumping apparatus or pit 

peculiarities and is secured so that the pump will shut off. 

It is recommended to use rigid piping and fittings and the 

pit be 12" or larger in diameter.     

3. 

 These pumps are not designed or intended 

to be used to handle sewage or effluent.

4. 

 Maximum continuous operating water tem-

perature for standard model pumps must not exceed 77°F 

(25°C).

5. 

 This pump has been evaluated for use with 

WATER only.

 

NOTE: A BATTERY BACKUP SYSTEM IS RECOMMENDED 

TO PREVENT FLOODING AND/OR PROPERTY DAMAGE 

IN THE EVENT OF MECHANICAL MALFUNCTION OR 

POWER OUTAGE.

 NOTE: 

Pumps with the “UL/CSA” mark are tested to UL 

standard UL778 and certified to CSA standard C22.2 No. 

108.

SEE BELOW FOR LIST OF CAUTIONS

SEE BELOW FOR LIST OF WARNINGS

MODELS 3CEH, 433063

 

SEE BELOW FOR LIST OF WARNINGS (CONTINUED)

8.

 

 RISK OF ELECTRIC SHOCK. These pumps 

have not been investigated for use in swimming pool ar-

eas.

9.

 

  This product contains chemicals known to 

the State of California to cause cancer and birth defects 
or other reproductive harm.

PUMP PERFORMANCE

Vertical Lift (Ft.)

Gal. per Hour

5

3000

10

2160

15

600

Shut off Head 16 Ft.