The FLP12 programmable thermostat, specially designed for floor
heating installations, is equipped with two ultra-precise sensors
which allow temperature control by separately monitoring both floor
and ambient settings, thus providing greater comfort.

The control module has four DIP switches to select the following
options:

Time and Temperature 
Display (1)

°F/12h

°C/24h (default)

Early Start (2)

E.S. On

E.S. Off (default)

This function determines the optimal system start time to obtain the
desired temperature by the set time. When this function is enabled, the
system can be activated a few hours before the program’s start time.

Temperature Control (3)

This model offers the following three types of temperature control: 

Permanent Backlight (4)

P.B. On (The display remains lit all the time.)

P.B. Off (default. The display is lit for 12 seconds when the
adjustment ring or any button is pressed.)

Align the bracket tabs on the
control module with the holes
located on top of the previ-
ously installed power base
and secure the module to the
base. 

NOTE:

Keep the thermostat's air vents clean and free from

obstructions.

First Power On

When power is applied for the first time, the
screen displays 0:00 MO (Monday) as well as
the ambient/floor temperature. 

If a problem occurs, one of the following mes-
sages will be displayed:

LO

:

the temperature is below 0°C (32°F) The 
heating indicator is displayed and the system is activated.

HI

:

the temperature is above 70°C (158°F).

Er

:

the floor sensor is not connected properly or defective (temp. 
control F) or the ambient sensor is defective (temp. 
control AF).

To verify if the thermostat detects the floor sensor, select the
temperature control F (see DIP Switch Configuration). If the screen
displays 

Er

, the floor sensor is not connected properly or defective.

If the screen displays the temperature, the sensor works.

DIP SWITCH CONFIGURATION

Temp. 

control

Switch 

position

Notes

Ambient with 

floor limits

DOWN (AF)

Requires a floor sensor

Floor 

(default)

UP (F)

Requires a floor sensor

Ambient

DOWN (AF)

Use only when floor sensor is 

not

 installed. 

Not

 recommended for floor heating

INSTALLATION

FLP12 - Control Module

User Guide

Current program number when 
Automatic mode is activated

Room or floor 
temperature. 
Arrow indicates
a setpoint

Indicates the amount 
of power sent to the 
floor heating system

Vacation 
mode

Current time 
and day

Economy setpoint

Manual 
mode

Temperature 
adjustment
ring

Day
setting

To program
and view the 
schedule

Comfort,
Economy and 
Vacation 
setpoints

ON/OFF—To turn On/Off the 
thermostat and GFCI reset

Time 
setting

To clear a 
program

To select a mode 
or to exit 
programming 
mode

Comfort setpoint

Floor 
minimum 
and 
maximum 
temperature 
(AF only)

GFCI test 
button and 
warning light

400-610-000-E (Flextherm FLP12 prog CAN) ENG.fm  Page 1  Friday, September 14, 2007  4:13 PM