18 Advanced functions
FLUXUS G722ST-HT
18.4 Remote functions
141
UMFLUXUS_G722ST-HTV1-2EN, 2021-09-01
18.4
Remote functions
Remote functions can be triggered by event triggers,
triggerable analog inputs or binary inputs.
In order to define an input for a remote function, it has to be
enabled in the menu item
Special functions\Inputs
.
In order to define an event trigger for a remote function, it has
to be enabled in the menu item
Options\Event trigger
.
It is possible to trigger one or more remote functions.
The following remote functions can be triggered:
• reset of measured values
• reset of totalizers
• stop of totalizers
Triggerable inputs and event triggers
The remote function is triggered if the switching condition is met. The remote function is reset as soon as the switching
condition is not longer met.
Binary input
The remote function will be triggered if a voltage in the active range is applied at the binary input:
• FLUXUS S721**-A20, FG721**-NN0: 5...30 V
• FLUXUS *72***-F20:
5...26 V
The remote function will be reset if the voltage at the binary input is switched back to the passive range (< 5 V).
18.4.1
Configuration of the remote function
• Select the menu item
Options\Remote functions
.
• Press ENTER.
In the scroll list of the functions it is displayed whether, and if so, which input or event trigger is assigned to a function.
• Select a list item:
– Reset meas. val. (-)
– Reset totalizers (-)
– Stop totalizers (-)
If an input or event trigger has already been assigned to this function, this is displayed as follows:
Reset meas. val. (R1)
.
• Press
to return to the previous menu.
Options
Remote functions
→ Reset meas. val.
→ Reset totalizers
→ Stop totalizers
With input
see annex A
Options\Remote functions