7 Connection
7.1 Transducers
FLUXUS F808
2020-06-25, UMFLUXUS_F808V2-2EN
72
7.1.12
Transducer module (SENSPROM)
The transducer module contains important transducer data for the operation of the transmitter with transducers.
If transducers are replaced, the sensor module must also be replaced.
• Disconnect the transmitter from the power supply.
• Insert the transducer module into the socket, see Fig. 7.18.
• Connect the transmitter to the power supply.
• Enter all parameters of the program branch
Parameter
.
• Start the measurement.
Notice!
The serial numbers of the transducer module and the transducer must be identical. A wrong or incorrectly connected
sensor module will lead to incorrect measured values or to a measurement failure.
Fig. 7.18: Connection of the transducer module
1 – transducer module
1