15 Data transmission
FLUXUS F401
15.3 Transmission parameters
95
UMFLUXUS_F401V2-1EN, 2020-06-12
• Press ENTER.
• Check the connections and make sure the PC is ready to receive data.
15.3
Transmission parameters
• the transmitter sends CRLF-terminated ASCII
• max. line length: 255 digits
RS232 interface
default: 9600 bits/s, 8 data bits, even parity, 2 stop bits, protocol RTS/CTS (hardware,
handshake)
The transmission parameters of the RS232 service interface can be changed.
• Enter the HotCode
232-0-
(see section 8.4).
• Set the transmission parameters in the 4 scroll lists.
• Press ENTER.
–
baud
: baud rate
–
data
: number of data bits
–
par
: parity
–
st
: number of stop bits
SERIAL ERROR
Print Meas.Val.
BAUD<data par st
9600 8bit EVEN 2