4.5 Mounting of silicone tubes
PD12 is equipped with a clear tube bridge cover, tube bridges and tube locks.
The clear tube bridge cover secures the tube bridges from being removed while the pump is running.
The tube locks ensure that the mounted tubes do not slide through the dispenser head when running.
The tube bridge retains the tube and performs the necessary pressure on the tubes.
Open the dispenser head by tipping each of the two locking pins up and lift the tube bridge
Figure 4-1 Removing the tube bridge
1
2
3
Mount the correct tube lock (1) on its dowel pin and place the tubes.
It is important that the tubes are situated in the two notches (2+3).
The Y-connector must be situated at the opposite side of the tube lock.
Now mount the tube bridge in its tracks and engage the two locking pins.
Figure 4-2 Mounting of silicone tubes
Place the clear tube bridge cover
over the tube bridges before attempting to start the pump.
NB! Never leave the pump mounted with tubes overnight.
At least tip the locking pins up in order not to retain the tube in
pressure