User Manual
LTU Orion 3
1
FlexDSL ORION 3
LTU DEVICES
TECHNICAL
DESCRIPTION
AND
OPERATIONS
MANUAL
Version
1.16
Document name
UM_Flexdsl-LTU-Orion3_V1-16.Docx
Revision
30. August 2018
Page 1: ...User Manual LTU Orion 3 1 FlexDSL ORION 3 LTU DEVICES TECHNICAL DESCRIPTION AND OPERATIONS MANUAL Version 1 16 Document name UM_Flexdsl LTU Orion3_V1 16 Docx Revision 30 August 2018...
Page 2: ...or as a whole transcribed stored in a retrieval system translated into any language or transmitted in any form or by any means electronic mechanical magnetic optical chemical photocopying manual or ot...
Page 3: ...7 3 2 2 3 2 Automatic V 54 Loops 28 3 2 2 4 Input Sensor and Output Relay 28 3 2 2 5 Ethernet Interface 29 3 2 2 6 MAC Filter 32 3 2 2 6 1 MAC Filter Rules 33 3 2 2 7 IEEE 802 1x Access Control 33 3 2...
Page 4: ...mand 69 4 6 3 13 LINKDIAG Command 69 4 6 3 14 M Command 70 4 6 4 Fault and Maintenance Management Menu 71 4 6 4 1 H Command 71 4 6 4 2 NM LINKNM Command 72 4 6 4 3 STATUS Command 72 4 6 4 4 STATUS ETH...
Page 5: ...Command 97 4 6 5 17 SETCLOCK list N 1 4 Command 97 4 6 5 18 MULTIPAIR 2 3 4 2 2 OFF Command 97 4 6 5 19 RESERVE list RESERVE list list Command 97 4 6 5 20 G704 ON OFF N Command 98 4 6 5 21 CRC4 ON OF...
Page 6: ...LE LAN1 5 RULE Command 120 4 6 5 78 DOT1X LAN1 5 OPTION Command 120 4 6 5 79 SETIP X X X X Command 121 4 6 5 80 NETMASK X X X X Command 121 4 6 5 81 GATEWAY X X X X Command 121 4 6 5 82 MTU Command 12...
Page 7: ...evices 145 7 1 1 Enter an Orion3 Device 145 7 1 2 Configure an Orion3 Device 145 7 1 3 Checking of Correct Working 148 7 1 4 Problem with Orion3 Device 148 7 2 Connector Description 149 7 2 1 Ethernet...
Page 8: ...ibute RFC 4133 Entity MIB partially supported RTS CTS DTR DCD or RTS DCD DTR CTS trigger for RSIP Rate example improved for IRATE CRATE ERATE commands RSTP commands improved 1 15 03 05 2018 1 7 8 New...
Page 9: ...be done by qualified personnel only EU DIRECTIVE 2002 96 EC AND EN50419 Our equipment is marked with the recycling symbol It means that at the end of the life of the equipment you must dispose it sep...
Page 10: ...Remote Power Source Console Port Management Telnet Management Web Management SNMP Management FG PAM SRL 2E1B 4Eth RP V90 1 2 FG PAM SRL 2E1B N64 4Eth RP V91 1 2 FG PAM SR2L 4E1B 4Eth RP V93 1 2 FG PA...
Page 11: ...R PROPERTY DAMAGE FLEXDSL TELECOMMUNICATIONS AG REFUSES NEITHER TAKING ANY RESPONSIBILITY NOR GRANTING ANY WARRANTY IN SUCH CASE WARNING ELECTRONIC MODULES CAN BE DAMAGED OR DECREASED IN RELIABILITY B...
Page 12: ...4 port Ethernet layer 2 managed switch with VLAN support 10 100BaseT ensures connectivity to IP services Beside of E1 and Ethernet we have additional interfaces like Nx64 that can be configured to be...
Page 13: ...AM SR2L 4E1B 4Eth RP V93 DB15 Male 1st 3rd E1 1 FG PAM SR2L 2E1B N64 4Eth RP V94 DB15 Male 1st 2nd E1 FG PAM SR4L 4E1B 4Eth RP V96 DB15 Male 1st 3rd E1 FG PAM SR4L 2N64 4Eth V98 HD26 Fem Nx64 FG PAM S...
Page 14: ...case one or both devices will be de energized Remote Power and Wetting Current Supply Modes NTU RR LTU Power DP Distance P Power LP Local P Remote Power Supply Wetting Current Supply Wetting Current C...
Page 15: ...DSL 4 XM52 DSL 1 XM54 DSL 2 XM51 DSL 3 XM53 DSL 4 XM42 DSL 1 2 XM50 DSL 3 4 XM47 DSL 1 2 XM48 DSL 3 4 XM55 DSL 1 XM58 DSL 2 XM56 DSL 3 XM57 DSL 4 Wetting Current Consumption Termination XM60 DSL 1 XM...
Page 16: ...r jumper location In the following two figures two main applications are showed for clarifying the description about remote power modes Figure 3 2 Example 120Volts 60mA XM58 XM57 XM55 XM56 XM47 XM48 X...
Page 17: ...SHDSL link The clock frequencies of different SHDSL channels are completely independent if they do not operate in the multipair mode An SHDSL channel working in the independent mode can simultaneousl...
Page 18: ...ter Slave Fix Configuration PAM16 3 60 2 Baserate 64 kbit s Annex A Annex B Annex AB autodetection PAM32 12 89 2 pair Master Autodetection PAM16 Auto 3 60 Annex AB autodetection PAM32 Auto 12 89 2 pai...
Page 19: ...he failed high priority channels At any failure the system always operates as if the low priority channels failed Consider the reservation with two channels DSL 1 and DSL 2 DSL 1 has a higher priority...
Page 20: ...L 2 Baserate 61 8 TS WAN 8 TS WAN 28 TS E1 2 1 TS WAN Total E1 1 E1 2 69 TS WAN E1 1 E1 2 8 TS WAN E1 1 28 TS E 12 1 TS WAN DSL 1 Baserate 72 DSL 2 Baserate 61 72 TS WAN E1 1 29 TS WAN 72 TS WAN Failu...
Page 21: ...table illustrates the logic of channel reservation with 2 3 4 SHDSL interfaces The table for four DSL channels is constructed based on the assumption that communication in one channel is lost frequent...
Page 22: ...receive nearly all configuration parameters for DSL and all other interfaces like E1 through the link from the Master Modem In a majority of cases they require just a minimum configuration what helps...
Page 23: ...link is supported The RCONF alarm displayed by the ALARM command means that the local and remote equipment have incompatible configurations The RCONF alarm is automatically not displayed if a DSL lin...
Page 24: ...the mode is disabled the modem transmits transparently CRC4 sub multiframes and checksum words if the generation of the zero time slot is not activated If the TS0GEN mode is activated the zero time sl...
Page 25: ...ERNAL inside subrack minirack UTT4 2 Clocking from the first E1 input stream E1 1 if available 3 Clocking from the second E1 input stream E1 2 if available 4 Clocking from the third E1 input stream E1...
Page 26: ...4 8192 kbps X 21 with termination Speed 64 8192 kbps V 28 synchronous Speed 64 192 kbps Interface type is cable selected You can use the command EXTRATE N N 1 128 to set the data rate N 64 kbps RS 232...
Page 27: ...to FIFO using the clock from line 113 and get out from FIFO by clock defined by SRC CONTRA contradirectional Transmit clock and transmit data have opposite directions i e transmit clock is an output f...
Page 28: ...supported by the system 3 2 2 4 Input Sensor and Output Relay FlexDSL Orion3 devices can be equipped with IO module containing 4 Inputs and 4 Outputs Input is a pair of contacts connected to current d...
Page 29: ...y in the data transmission an extended Ethernet frame is used which contains an additional VLAN tag of 2 bytes length The tag includes the number of the VLAN to which the packet belongs and its priori...
Page 30: ...oS In Trunk mode only tagged frames pass into and out of LANx port frames are allowed to pass on per VLAN basis This means that special equipment supporting VLAN is connected to the Trunk port A PC wi...
Page 31: ...E 802 1Q VLANs as well as port based VLANs allow creating separate logical networks on one physical network Thus in different VLANs or PBVLANs there could be devices sharing the same MAC address On Or...
Page 32: ...erface means that Ethernet data can be mapped onto specified timeslots 64kbit s on the E1 interface by using the internal switch In this case this port always serves as a Trunk port A virtual manageme...
Page 33: ...ed as multipoint to multipoint media for simple and secure point to point authorization It works on MAC level and provides Authentication and Authorization for a terminal device connected to a port of...
Page 34: ...interfaces are combined into MULTIWAN this MWAN will participate in RSTP construction too The RSTP itself is a protocol used for dynamic link switching in networks with ring topology The ring topology...
Page 35: ...E WILL BE IN BLOCKED STATE 3 2 2 9 RADIUS The RADIUS Remote Authentication in Dial In User Service is used to authenticate and authorise remote devices from the single place Unlike the local authentic...
Page 36: ...rver didn t reply the client tries the first server again This sequence keeps running until the number of retries counter expires The number of retries is user defined If the whole authentication sequ...
Page 37: ...dius clients conf FlexDSL Orion3 Clients Modems from network 192 168 1 0 24 will be authenticated using secret phrase Don t forget to add sharing secret to Orion3 modem using RADIUS SECRET command cli...
Page 38: ...ion3 User with Read only rights ORION3OPERATOR Cleartext Password OperatorPass Vendor Specific TEST Vendor Specific STATUS Framed IP Address 192 168 1 0 Framed IP Netmask 255 255 255 0 Without Vendor...
Page 39: ...ing configuration using sudo service freeradius restart command 3 2 2 9 4 Configuring User Access Rights The Vendor Specific or FlexDSL Rights or Service Type field in RADIUS configuration tells the c...
Page 40: ...All commands from LAN reset of Ethernet counters and MAC table RESETNETSTAT MACTABLE C ALL CONFIG C VIEW Displaying of device configuration CONFIG NETCONFIG COSCONFIG RSTP CONF LINK All commands from...
Page 41: ...heir capabilities to their peers over IEEE 802 Ethernet networks or over WAN MWAN channels formed via DSL E1 links LLDP protocol is vendor neutral so various devices can interoperate and introduce the...
Page 42: ...transmission in the SHDSL line interface in the ascending order are transmitted in time slots from 0 to m1 1 time slots of the second E1 chosen for transmission in the SHDSL line interface in the asc...
Page 43: ...aster and Slave devices as well as for the Regenerator The LOOP1 ON OFF N command is used to activate deactivate LOOP1 where N is the number of the network interface LOOP2 M N where M is the number of...
Page 44: ...ation and maintenance procedures whereas the G 826 error performance parameters are used for long term evaluation of operating links and during acceptance testing The Noise Margin NM provides qualitat...
Page 45: ...rror rate is not within the scope of G 826 calculations 3 2 5 BERT Test We suggest BERT testing in the following way Switch on Loop2 on the remote unit slave and setup the BERT on the master unit Figu...
Page 46: ...4 Status 4th Ethernet Interface 3 4 RP LED Status RP remote power 3rd DSL LED Status RP 4th DSL 1 2 LED Status RP remote power 1st DSL LED Status RP 2nd DSL 1 3 SHDSL Status 1st DSL line Status 3rd DS...
Page 47: ...escription LOS DSL Urgent R R R Loss of signal in an SHDSL link LOSW R R Loss of frame alignment in an SHDSL link LOSD R R Loss of signal at the remote SHDSL side BER H R R Block error rate in an SHDS...
Page 48: ...alarm AIS S A Receiving AIS on the E1 side BER S A Excessive block error rate on the 1 side LOOP1 A Loop is activated towards the 1 equipment AIS R A Receiving AIS on the E1 side of a remote device E...
Page 49: ...4 1 Management by Local Craft Terminal or MONITOR Interface RS 232 Interface Orion3 LTU devices have at the backplane connector a TTL voltage level management bus that is organized according to the p...
Page 50: ...ssion Orion3 subrack devices LTU can choose the command NNN to manage other devices NNN are digits and symbols of the Latin alphabet in the range from 0 to 80 This command is used to configure Orion3...
Page 51: ...e used to access the WEB interface To display the statistics you should enter the command http X X X X or https X X X X in the WEB browser X X X X is the IP address of the modem After the connection i...
Page 52: ...rameters in the tables are refreshed every 5 seconds Click the button in the left part of the window of the WEB browser to display the necessary table The software version is also displayed in the lef...
Page 53: ...User Manual LTU Orion 3 53 Figure 3 24 WEB interface Orion 3 DSL Status Statistics G 826 WAN Net Statistics E1 Statistics TCP IP ICMP Statistics...
Page 54: ...s to be imported into the SNMP Server for the purpose of translation the Object Identification OID numbers and their content to the human readable format For example it is requested to check the statu...
Page 55: ...the SNMP protocol version the following SNMP messages are supported for the SNMP V1 GET GET NEXT SET TRAP for the SNMP V2c GET GET NEXT GET BULK SET TRAP for the SNMP V3 READ WRITE TRAP GET and READ m...
Page 56: ...cepted by an intruder Therefore User data such as login and password credentials can be safely transmitted over public networks The Orion3 modem acts as SSH server It listens default TCP Port 22 for i...
Page 57: ...ABLE C MULTIPAIR 2 3 4 2 2 OFF MACTABLE 1 8 OTHER Port RESERVE list1 list2 MACTABLE G704 ON OFF N LLDP STAT IF ALL CRC4 ON OFF N STARTAL N AISDET ON OFF N RESTART N AISGEN ON OFF N RESET DSLTS list N...
Page 58: ...AN N 0 3 OFF SNMP V1 V2C V3 ON OFF SNMPACL 1 2 IP OFF TRAPIP 1 2 IP OFF TRAP 1 2 V1 V2C TRAP 1 2 V3 RO RW COMMUNITY COMMUNITY GET SET TRAP SNMPSET ON OFF SNMP RO RW NAME SNMP RO RW AUTH MODE SNMP RO R...
Page 59: ...equally The running configuration is stored in the RAM of the device The current parameters determine the operation until the next restart or any actions on the running configuration storage and etc...
Page 60: ...he new configuration into the running configuration and the device starts working according to these configurations The administrator also can confirm changes in all groups After the received running...
Page 61: ...second connection within 30 minutes If within this time the operator did not enter the modem menu the changed parameters are read from the startup configuration of the unit Therefore it is possible t...
Page 62: ...and press enter 4 6 1 1 System Invitation The following format of the system invitation is used in all menus cc _ addr _ sf is the device mode RR Regenerator CO Master CP Slave CX Modem with both typ...
Page 63: ...provisioned for regenerators 4 If the channel of remote management is blocked for example a message or a table are not displayed completely press Enter 4 6 2 4 LINK SN 00 FE Command The LINK SN 00 FE...
Page 64: ...larm log ALARMLOG C Clear the link alarm log LINKNM Trace xDSL noise margin of all accessible units LINKDIAG Trace xDSL status of all accessible units APPLY ALL GROUP Apply changes to running configur...
Page 65: ...RC4 1 E Bit 2 CRC4 2 E Bit 3 CRC4 3 E Bit 4 CRC4 4 E Bit EB 00000000 00000000 00000000 00000000 00000000 00000000 00000003 00000002 ES 00000000 00000000 00000000 00000000 00000000 00000000 00000001 00...
Page 66: ...tio of BBE to the total number of error free seconds in available time during a fixed measurement interval Available time The period when measurements of the parameters are possible Unavailable time T...
Page 67: ...NMP tables defined by RFC1213 MIB IF MIB and RMON MIB 4 6 3 8 NETERR LAN WAN Command This command shows the main network LAN or WAN MWAN interface error counters CO_PM NETERR WAN Interface WAN1 WAN2 W...
Page 68: ...even when no error Total number of received packets with size 64 bytes 68 when tagged Total number of received packets with size 2040 bytes 2044 when tagged Received packets that were undersized and...
Page 69: ...s important parameters of DSL link for local unit remote unit and for connected repeaters CO_06_FMM LINKDIAG Querying link data DSL1 DSL3 DSL Unit NM G 826 ES Status Alarms Description 1 local CO 19 0...
Page 70: ...t acts as Slave modem NM dB Noise Margin G 826 ES ES Number of seconds with errors According to G 826 Status up down pre act act Link is UP Link is Down Link is preparing for activation Link is activa...
Page 71: ...ation ACO GROUP ON OFF Change alarm indication for alarm group GROUP MACTABLE C Clear MAC table MACTABLE 1 8 OTHER Port Print MAC table for VLAN port MACTABLE Print all MAC table entries LLDP STAT IF...
Page 72: ...0 0 0 0 dB Bitrate 0 0 0 0 kbit s SRU 0 0 0 0 Active sync source Internal Internal Internal Internal Remote power state 120V ON OFF 120V ON OFF Temperature 42 875 C Option T update the table continuo...
Page 73: ...rhood CX_06_FMM STATUS LLDP MWAN1 neighbour Port description MWAN2 Management address 192 168 1 26 Chassis ID 00 0f d9 05 5e 61 Port ID MWAN2 System description FG PAM SA4N 2Eth V84 LABOR SW 1 6 17 HW...
Page 74: ...MAC address either passed authentication Auth or transmits traffic Pass or in blocking state Block 802 1x mode Ether MAUTH MHOST or SHOST 4 6 4 9 STATUS ENCODE Command This command shows status of enc...
Page 75: ...hannel systems the parameter N is not obligatory The parameters N 1 13 activates the loop back on the Regenerator whose number is specified by the value of N The regenerators are numbered starting fro...
Page 76: ...ored frame alignment segment alarm NM Noise Margin NM threshold LA Loop Attenuation LA threshold LOOP2 A loop is activated on the line interface of a remote device in the direction of the local device...
Page 77: ...rm IN x Digital Input The deactivated alarms do not generate any urgent or non urgent alarms i e does not affect the colour of LEDs on the front panel and alarm relay status Note By default the Ethern...
Page 78: ...LABOR SW 1 6 17 HW 1 4 System capabilities system 0x4 enabled 0x4 Management address IPv4 192 168 1 26 ifIndex 2 5 Management VID 1 Maximum frame size 2048 MED capabilities device type 1 capabilities...
Page 79: ...e CP_FMM RESET 4 6 4 19 CONFIRM Command This command confirms the running configuration and writes it to the startup configuration As a result after confirmation of the configuration variables changes...
Page 80: ...ollows CO_FMM DIFF N R New configuration Running configuration No differences No differences CO_FMM 4 6 4 23 DUMP N R S B Command This command displays the dump of the corresponding configuration New...
Page 81: ...the external alarm status of Regenerators CO_01_FMM TLM Distant external alarms status Line 1 Line 2 Line 3 Line 4 ALM1 ALM2 ALM3 ALM1 ALM2 ALM3 ALM1 ALM2 ALM3 ALM1 ALM2 ALM3 RR01 off off off off off...
Page 82: ...MAJ MAJ MAJ MAJ MAJ MAJ RR05 MAJ MAJ MAJ MAJ MAJ MAJ MAJ MAJ MAJ MAJ MAJ MAJ RR06 MAJ MAJ MAJ MAJ MAJ MAJ MAJ MAJ MAJ MAJ MAJ MAJ RR07 MAJ MAJ MAJ MAJ MAJ MAJ MAJ MAJ MAJ MAJ MAJ MAJ RR08 MAJ MAJ MAJ...
Page 83: ...DSL3 Config OFF Status OFF Alarms RP source 2 Mode 2x120V Leakage DC 215uA AC 8uA DSL2 Config OFF Status OFF Alarms DSL4 Config OFF Status OFF Alarms 1 Leakage analysis M Exit Pressing 1 AC analysis...
Page 84: ...Download the startup configuration from the TFTP server In this case ARG1 should contain the IP address of the TFTP server and ARG2 should contain the path to file with the configuration CERT Downloa...
Page 85: ...the corresponding line fixed First basic software Cannot be downloaded does not require confirmation just loaded Downloaded second software not confirmed Non confirmed second software confirmed Confir...
Page 86: ...rd will be downloaded to the unit 4 6 4 41 SD STATUS Command The SD status command shows if the SD BOOT is enabled and the SD card information CO_01_FMM SD STATUS SD Boot OFF Card type SDHC Capacity 3...
Page 87: ...ace BERT statistics SHOW Show BERT statistics once RES Reset BERT statistics SET E11 E12 INT EXT Set BERT interface PATD 2En bitstring Set BERT pattern TS TX RX list NONE Set controlled slot list CONF...
Page 88: ...access rights USER name IP subnet Set IP access list for user USER name LOCAL ALL Set all IP or local only user access PASSWORD user Set user password AUTO ON OFF Set CA mode CONFIG Display local con...
Page 89: ...lected WAN channel N CP_CM ENCODE KEY 1 Please enter encryption key mykey1 Please repeat encryption key Encoding WAN1 WAN2 WAN3 WAN4 Destination DSL1 DSL2 DSL3 DSL4 Key set set set set Enabled yes yes...
Page 90: ...le to access the WEB interface and the CLI only if source IP address belongs to the defined domain Starting from the software version 1 5 1 the Advanced Security option activates SSH and Radius protoc...
Page 91: ...means that the commands from low levels will be selected too Some commands are available for every user they can t be revoked Privileges Hierarchy Levels Description Related commands Top Level Group...
Page 92: ...PSET SNMPACL RMONALARM RMONEVENT APPLY CONFIRM NET All commands from VIEW IP configuration SETIP GATEWAY NETMASK MTU SYSLOG SNTP APPLY CONFIRM PING Note The abridgements in braces can be entered inste...
Page 93: ...password only to access the device over the telnet protocol When managing the devices via the RS 232 interface the password is not requested 4 6 5 9 CONFIG N R S B Command The CONFIG command always di...
Page 94: ...nterface kbit s Table 4 4 All possible configurations of independent channels The main operation modes of any device are Independent channels CO P CX Independent channels with reservation CO P CX Mult...
Page 95: ...1 4 Command This command activates deactivates the MASTER mode on the interface with the number N For single channel modems the command is used without the number of the SHDSL channel CP_01_CM MASTER...
Page 96: ...ected opposite Annex in the CONFIG configuration AB appears opposite PAM is Auto The command does not change the Annex and PAM modes in the configuration In the Slave mode the BASERATE AUTO command au...
Page 97: ...he command Two rules The list of priority clock sources should contain only those E1 Nx64 or E0 channels which are used to transmit data over the SHDSL channel If the SHDSL channel does not transmit a...
Page 98: ...ce The AISDET ON OFF N command activates deactivates the AIS Detection mode for the E1 interface where N is the number of the E1 interface CO_CM AISGEN ON 1 CO_CM AISDET ON 1 4 6 5 23 DSLTS list NONE...
Page 99: ...eration mode where N is the mode number there are four default operation modes The DEFAULT 0 command sets the following mode SLAVE PAM 32 BASERATE 89 ANNEX B transmission of the E1 stream and Ethernet...
Page 100: ...AN DSL and E1 interface names are automatically converted to corresponding WAN channels by this command 4 6 5 37 PTMP SHOW Command This command shows the members of the Point to Multipoint group chann...
Page 101: ...below 1024 may be used as well as port numbers above 1024 but may conflict with another built in services like SNMP or NTP It s not recommended to use ports below 1024 mode Selects the IP protocol and...
Page 102: ...Enable RS IP RSIP UDP RS Select UDP mode RSIP IN 5000 RS Means to select port 5000 for the reception of serial data packets RSIP OUT 172 16 53 1 5000 RS Select IP address 172 16 53 1 and port 5000 as...
Page 103: ...User Manual LTU Orion 3 103 TCP Point to Point COM Server...
Page 104: ...X 21 or N 1 7 V 28 in this case the Nx64 data rate will be Nx64 kbps For the RS232 and RS485 interfaces N is the baudrate 9600 for instance N 1200 256000 4 6 5 47 AUTOLOOP OFF ALL DATA Command This c...
Page 105: ...Shut down interface IN x or OUT x NO Specifies that interface IN x is normally opened NO or normally closed NC In NO state the current absence means no Alarm generation Alarm will be generated if the...
Page 106: ...ce IN 1 IOIP LOCAL 5001 IN 2 Set local port for interface IN 2 IOP REMOTE 192 168 0 1 5000 IN 1 Set remote destination for interface IN 1 IOP REMOTE 192 168 0 1 5001 IN 2 Set remote destination for in...
Page 107: ...Set default QoS for access ports ALLOW IF VLAN list Set list of VLANS to allow on trunk interface VID 1 8 ID Assign VID to the VLAN specified MACLIST SHOW Show MAC filter settings MACLIST SHOW N R S B...
Page 108: ...n SSH TELNET HTTP ON OFF Enable disable management servers SSH PORT N Set TCP port for SSH service SSL SHOW DEL options Manage SSL certificate and private key RADIUS 1 2 SECRET Set shared key for Radi...
Page 109: ...VLANs which are configured separately Pluses and minuses mark transmission locking of VLAN for each of interfaces OTHER VLANS Configurations for other VLANs which are not configured separately Pluses...
Page 110: ...NETCONFIG N R S B command displays one of four configurations New Running Startup or Backup depending on the parameter After successful execution of a command that changes any parameter showed by NETC...
Page 111: ...4 6 5 55 RSTP A E ON OFF Command RSTP system creates separate instance for each PBVLAN Every instance will work only with ports included in specific PBVLAN It means that up to 5 RSTP instances could b...
Page 112: ...discards incoming traffic o Forwarding Delay in seconds Learning port learns information about peer MAC RSTP priority etc o Forwarding Delay in seconds Forwarding port forwards traffic Forwarding Del...
Page 113: ...ket Age Age 1 Age 1 Input Age 1 Max Age 6 Age Max Age Yes forward packet Age Age 1 Age 2 Input Age 2 Max Age 6 Age Max Age Yes forward packet Age Age 1 Age 3 Input Age 3 Max Age 6 Age Max Age Yes forw...
Page 114: ...tus fast escaping the Learning phase RSTP IFACE EDGE OFF command means that the port will never become Edge It will change all its phases and always will send RSTP BPDUs in egress direction RSTP IFACE...
Page 115: ...0000 Yes 8002 LAN2 DOWN AUTO 8003 LAN3 DOWN AUTO 8004 LAN4 DOWN AUTO 8005 LAN5 DOWN AUTO 8006 WAN1 UP Disc Alt 5 696Mbit AUTO 3511235 No 8007 R WAN2 UP Fwd Root 5 696Mbit AUTO 3511235 No 8008 WAN3 DOW...
Page 116: ...00 00 00 2 MWAN2 0 00 00 00 00 00 00 RSTP E 32768 00 0F D9 04 A7 25 1 MWAN1 0 00 00 00 00 00 00 2 MWAN2 0 00 00 00 00 00 00 CX_06_NET 4 6 5 67 PBVLAN IF A E Command This command assigns the network i...
Page 117: ...e LAN traffic separation is needed can be made with PBVLANs only or VLANs only In some setups PBVLANs way has benefits in some the VLAN way Mix of VLANs and PBVLANs is also convenient in some applicat...
Page 118: ..._NET ALLOW LAN1 1 2 3 CP_01_NET ALLOW WAN2 5 3 OTHER CP_01_NET ALLOW WAN4 ALL 4 6 5 72 VID 1 8 ID Command The VID 1 8 ID command sets VID for the VLAN with the number 1 8 equal to the ID parameter ID...
Page 119: ...e7a0b 3 0090cc 3e7a0b 4 0090f5 3e7fac 5 6 7 8 9 10 It is allowed to use interface number or interface name for example LAN1 as IF parameter System accepts or symbols as MAC address separator It is pos...
Page 120: ...CX_05_NET MACRULE 4 INDICATE New MAC Filter Configuration Port LAN1 LAN2 LAN3 LAN4 LAN5 Mode ON FILTER ON INDICATE ON BLOCK OFF INDICATE OFF FILTER White list 1 0090f5 3e7a0b 0090f5 bb7a0b 0090f5 bb7a...
Page 121: ...6 5 80 NETMASK X X X X Command The NETMASK A B C D command sets the subnet mask of the modem 4 6 5 81 GATEWAY X X X X Command The GATEWAY X X X X sets the default IP address of the router 4 6 5 82 MTU...
Page 122: ...lectable VLAN and QoS settings If incoming traffic has bigger bandwidth then selected by IRATE command the excess will be dropped if Flow Control is disabled on the port or the switch will send so cal...
Page 123: ...SS mode He has to be sure that those LAN ports of the device have different default QoS or VLAN settings ERATE rate Sets the desired rate limit ERATE OFF Disable rate limiting The parameter rate is ex...
Page 124: ...s 128 kbps 256 means 256 kbps 1M means 1000kbps 30M means 30000kbps 4 6 5 89 COS QOS VLAN N 0 3 OFF Command This command sets the VLAN to CoS and QoS to CoS mapping COS VLAN QOS V 1 8 Q 0 7 CoS 0 3 OF...
Page 125: ...figure and manage the device however this command makes the device sensitive to attacks over SNMP in unprotected PC networks The SNMPSET OFF command disables processing SNMP SET requests what protects...
Page 126: ...e to add up to 2 Syslog severs The SYSLOG command is used for that purpose SYSLOG 1 2 x x x x set 1st or 2nd IP address in x x x x format SYSLOG 1 2 OFF remove 1st or 2nd IP address 4 6 5 101 LLDP ON...
Page 127: ...n the local LLDP subsystem The recommended Transmission_Delay value is represented by the following formula 1 Transmission_Delay 0 25 Retransmission_Interval Notification Interval This parameter indic...
Page 128: ...sabled CX_06_NET 4 6 5 107 SNTP 1 2 IP OFF Command The Syslog protocol should carry the real time stamp in every message For this reason the SNTP protocol RFC 2030 has been implemented The SNTP protoc...
Page 129: ...LH OCT firstSUN 5 02 00w 30min APR firstSUN 6 02 00w 0min Lord Howe Island W Eur MAR lastSUN 30 01 00s 60min OCT lastSUN 26 01 00s 0min Western Europe NZ SEP lastSUN 28 02 00s 60min APR firstSUN 6 02...
Page 130: ...n you change time NN Particular month day number like 5 or 30 firstDDD First week day in the month with name DDD DDD is three letter abbreviation of day name MON TUE WED THU FRI SAT SUN lastDDD Last w...
Page 131: ...4 6 5 111 SSH PORT N Command changes port the SSH server listens for incoming connections CO_04_NET SSH PORT 2022 Running Network Configuration cut Service settings Running Port TELNET SSH 2022 HTTP...
Page 132: ...Q 2ZHBbi5NsWX K1pG8tOMFn13wnI9RA adw0Lmu4tOLTEhHbczXd7Lf50LXDV5PuAFkvNppM1En0sCOPJZVf END RSA PRIVATE KEY 1676 bytes Usage SSL SHOW DEL CERT KEY CA Parameter Description SHOW DEL To display or to dele...
Page 133: ...il to give a reply within a defined timeout the client sends request to the second RADIUS server The requests keep going until the number exceeds the number of retries then the client will use local r...
Page 134: ...pending on the parameter 4 6 5 119 NETDEFAULT Command The NETDEFAULT command sets the following configuration The MAC address of the modems takes the manufacturer value The default IP address sub netw...
Page 135: ...232 Port LCT Using the Flash Loader Program To download the software on any Orion3 device do the following steps 1 Power off the device You may extract the unit a little from the subrack minirack or...
Page 136: ...User Manual LTU Orion 3 136 5 Select Select Device in the Setting menu then select FG PAM and click Ok 6 Select the xxx SSS file and click Open...
Page 137: ...User Manual LTU Orion 3 137 7 Select Connect COM in the Action menu 8 Power on the device activate You may insert the unit to the subrack minirack or UTTx housing 9 Click Yes in the Flashloader window...
Page 138: ...r Send Panel 11 If the downloading was successful the following window will be displayed 12 Click Ok 13 Select Disconnect COM in the Action menu 14 Power off the device being loaded and disconnect it...
Page 139: ...2 connector of the device Monitor LCT with the Com port RS 232 of the Personal Computer 3 Run the Hyper Terminal program hypertrm exe 4 Create a new connection in the Connection Description window Inp...
Page 140: ...he COM port COM properties Click k Bits per second 9600 Data bits 8 Parity None Stop bits 1 Flow control None 7 Select Properties in the File menu of the HyperTerminal program 8 Select the Setting tab...
Page 141: ...ayed 11 Go to the Fault and maintenance management menu means to enter number 2 Enter the SOFTUPDATE command After typing SOFTUPDATE the device tries to establish connection over the X modem protocol...
Page 142: ...are is downloaded the 1K Xmodem file send for window closes automatically 15 After the software is downloaded completely enter the RESET command in the Fault and maintenance management menu After this...
Page 143: ...ervice center 7 Defects of the system into which this product is included If the equipment should be powered from a primary DC source 38 72 V please us it with the grounded Before applying primary AC...
Page 144: ...t match the CRC4 error counter is incremented The G826 command is used to display the G 826 statistics The correctness of operation and configurations of network interfaces can be checked by using loo...
Page 145: ...ess ENTER Telnet through Ethernet Interface Type in command line Telnet 192 168 0 235 and press ENTER This is the default Ethernet Address for Orion3 devices After a successful entering the main menu...
Page 146: ...0 101 Set the default gateway M Go to Configuration Management CM M Go to Main Menu 2 Go to Fault and maintenance management FMM APPLY ALL Apply all configurations written in the running config CONFIR...
Page 147: ...n the running config CONFIRM Confirm all configurations written in the startup config In Menu Configuration Management CM you can type CONFIG to see the following picture CP_01_CM CONFIG Running Line...
Page 148: ...system status CP_01_FMM STATUS Status DSL1 DSL2 DSL3 DSL4 I F mode CO CO CO CO SYNC 1 1 1 1 SEGD 1 1 1 1 Power backoff 0 0 0 0 0 0 0 0 dbm Far end power backoff 0 0 0 0 0 0 0 0 dbm Loop attenuation 14...
Page 149: ...t used 8 NC not used 7 2 3 E1 120 Ohm Connector Type DB 15 D Sub male 15 pins Pin No Signal Description 1 TX_1 2A E1 Output CH1 2 Wire A 9 TX_1 2B E1 Output CH1 2 Wire B 2 FPE Functional Protective Ea...
Page 150: ...nput CH1 2 Wire A 2 E1 Input CH1 2 Wire B 3 NC not used 4 E1 Output CH1 2 Wire A 5 E1 Output CH1 2 Wire B 6 NC not used 7 NC not used 8 NC not used Please order FG ADAPT E1B RJ45 to convert DB 15 conn...
Page 151: ...Data A 104a DTE 10 RXD B Rb Receive Data B 104b DTE 24 RTS A Ca Request to Send A 105a Control A DCE 15 RTS B Cb Request to Send B 105b Control B DCE 26 CTS A Ia Clear to Send A 106a Indication A DTE...
Page 152: ...ention the RS 232 daughter board is different than the Nx64 daughter board Type DB 26H D Sub High Density female 26 pins Pin No Signal RS 232 Description Direct 1 TXD 1 Transmit Data 1 In 2 RTS 1 Requ...
Page 153: ...64 daughter board Type DB 26H D Sub High Density female 26 pins Pin No Signal RS 485 422 RS 232 Description Direct FD HD 7 TXD1 TXD RXD1 RXD1 Transmit Data Out 9 RXD1 TXD1 Receive Data In 3 TXD1 TXD R...
Page 154: ...nsmit Data Out 5 Signal Ground 14 Signal Ground 22 Signal Ground 23 Signal Ground 15 Cable is Connected In This connector description is only correct with the codirectional G 703 E0 64 kbps daughter b...
Page 155: ...rion3 Nx64 to X 21 DB26MH to DB15F DTE 1 0m UL2464 AWG 28 OD 5mm FG CAB N35 OR3 DCE Cable Orion3 Nx64 to V 35 DB26MH to MRAC34M DCE 1 0m UL2464 AWG 26 OD 8 5mm FG CAB N35 OR3 DTE Cable Orion3 Nx64 to...
Page 156: ...Connector ACU Minirack UTTx Type DB 9 D Sub female 9 pins Pin No Signal Description 1 PG Protection ground 2 TXD Transmit data to the modem 3 RXD Receive data from the modem 4 ND_COM DA_COM Non urgen...
Page 157: ...ected In 9 OUT1nc Output 1 normally closed Out 18 OUT1com Output 1 common Out 26 OUT1no Output 1 normally open Out 8 OUT2nc Output 2 normally closed Out 17 OUT2com Output 2 common Out 25 OUT2no Output...
Page 158: ...nnector Type either DB15 male 120 or two BNC 75 ESD Protection 8kV Air discharge 8 1 3 Nx64 and RS 232 RS 485 Interface Specification ITU T Rec V 35 V 36 X 21 V 28 or RS 232 485 Number of Interfaces 1...
Page 159: ...per card 4 Max Input Voltage 72VDC Isolation 2000Vrms Output Voltage 3 3V 5 Maximal Output Current 20mA Number of Outputs per card 4 Maximal switching Voltage 120VDC 1A Maximal switching Power 30W Is...
Page 160: ...range available on request 20 C 80 C 8 3 2 EMC and Safety Standards EN 300386 V1 4 1 2008 EN 50121 4 2006 EN 60950 1 2006 EN 55022 2006 Class B EN 55024 A2 2003 EN 61000 4 2 A2 2001 EN 61000 4 3 2006...