background image

Installation, Operation, & Maintenance Guide

Style 78HT

Figure 8: Step

5

.

Figure 9: Step

10

.

Figure 10: Step

12

.

.050

DESIGN GAP

Figure 11: Style 78HT layout.

SEAL SUPPORT SYSTEM INSTALLATION

The following steps briefly describe the methods in which a buffer/barrier system should be piped and set up to
support a double cartridge seal. Consult Flexaseal for specific applications and details.

1

. Correctly make connections between the buffer/barrier fluid system and the mechanical seal according to

the connection labels on the prints. In the case of a Piping Plan 52 or Plan 53A the

SEAL SUPPLY

connection (lower port) on the reservoir must lead to the buffer/barrier fluid in (

BFI

) connection on the seal

gland; the

SEAL RETURN

connection (upper port) on the reservoir must lead to the buffer/barrier fluid out

(

BFO

) connection on the seal gland (

Figure 12

).

• Piping should slope continuously upwards (

1

2

in./ft. [40 mm/m] minimum) with no relative high points

that would result in trapped air in the tubing.

• For shafts smaller than 2

1

2

in. [64 mm] use at least

1

2

in. diameter tubing and at least

3

4

in. tubing for

larger shafts.

• Use smooth, long radius bends in the piping, minimize 90

elbows, and use 45

bends wherever

possible.

Page 5 of 9

Summary of Contents for 78HT

Page 1: ...venue Houston Williston VT 05495 Bom Retiro Sao Paulo Gonzales LA 70737 7545 E Orem Drive Brazil CEP 01130 010 Houston TX 77075 TEL 832 804 7424 TEL 802 878 8307 TEL 55 11 3736 7373 TEL 225 484 0007 F...

Page 2: ...ended application 4 Inspect the replacement seal prior to removal of the old seal or installation of the new seal using the technical information provided in this document Contact a Flexaseal represen...

Page 3: ...ber face of rust burrs grit sharp edges and set screw damage using fine emery cloth Wipe clean Avoid making flat spots or reducing the shaft diameter 4 If the pump is equipped with a shaft sleeve veri...

Page 4: ...t 0 0015 0 003 in Fig 3 Radial bearing fit 0 002 0 003 in Fig 4 Bearing frame perpendicularity 0 0005 in in Fig 5 Axial shaft movement end play 0 003 in Fig 6 Seal chamber bore concentricity 0 005 in...

Page 5: ...d from Flexaseal with the drive collar cap screws finger tight 5 Lightly lubricate the sleeve packing with a suitable and compatible lubricant Slide the drive collar and the sleeve packing along the s...

Page 6: ...els on the prints In the case of a Piping Plan 52 or Plan 53A the SEAL SUPPLY connection lower port on the reservoir must lead to the buffer barrier fluid in BFI connection on the seal gland the SEAL...

Page 7: ...lting in damage to and premature failure of the mechanical seal Ensure that all tubing piping is free of pipe strain which can adversely affect the seal 2 Flood the seal support system with the recomm...

Page 8: ...f leakage is detected it should be addressed as soon as possible to prevent hazards and protect personnel Leakage could come from a number of leak paths in the seal or be caused by changes in the pump...

Page 9: ...e of all fluids contained in the pump drain and decontaminate before opening the housing for seal service 1 Ensure all fluid has been drained and vented Equipment should be shut down and locked tagged...

Page 10: ...ect to misuse misapplication neglect alteration accident or physical damage c have been used in a manner contrary to FAS s instructions for installation operation and maintenance d have been damaged f...

Reviews: