background image

FLEX-PRO

Peristaltic Metering Pump

R

SERIES  A2

Operating Manual

system

TF D

Tube Failure Detection

Exclusive:

2

TWO-YEAR

WARRANTY

ProSeries

Protected by Patents: 7,001,153; 

7,284,964;  4,496,295

and other patents pending

Patent No. 7,001,153 & 7,284,964

CERTIFIED FINAL DOCUMENT

CALL 1-800-577-8111 FOR SALES AND SUPPORT

CLICK HERE TO RETURN TO WEBSITE

Summary of Contents for A2V24-GE

Page 1: ...R SERIES A2 Operating Manual system TFD Tube Failure Detection Exclusive 2 TWO YEAR WARRANTY ProSeries Protected by Patents 7 001 153 7 284 964 4 496 295 and other patents pending Patent No 7 001 153...

Page 2: ...s part of our stringent quality assur ance program at Blue White Industries Flex Pro TABLE OF CONTENTS Section Heading Page 1 0 Introduction 2 1 1 Available Models 3 2 0 Specifications 4 2 1 Materials...

Page 3: ...01 1 4 220V AC A3V26 ND A2V26 NH ML Min 7 700 09 90 Feed Rate RPM 125 125 Max Speed A3 Model Numbers PSI bar 65 65 65 4 5 4 5 4 5 Max Pressure PSI bar 125 8 6 125 8 6 PSI bar 65 4 5 Max Temperature F...

Page 4: ...0V60Hz NEMA 6 15 USA 220V50Hz CEE 7 VII EU 240V50Hz AS 3112 Australia New Zealand Duty cycle Continuous Enclosure 413 Aluminum Polyester powder coated Pump Head q Valox PBT thermoplastic Pump Head Cov...

Page 5: ...clockwise and counter clockwise Output rates to 17 GPH 64 LPH and pressures to 125 PSI 8 6 Bar Variable speed DC motor Specially engineered tubing for long life at high pressures Meets FDA 21 CFR req...

Page 6: ...ms are strictly for guideline purposes only Always consult an expert before installing metering pump on specialized systems Metering pump should be serviced by qualified persons only n Raise metering...

Page 7: ...ecting chemicals that calcify such as sodium hypochlorite Duckbill may add additional back pressure to pump up to 7 psi 3 8 OD x 1 4 ID Tubing and Tri Clamp connection Models Proper eye and skin prote...

Page 8: ...and power cables together Power Interruption This pump has an auto restart feature which will restore pump to operating state it was in when power was lost Note When in doubt regarding your electrical...

Page 9: ...isplay will read OFF if pump has been stopped in this manner Pump will not respond to incoming input signals while in OFF state When START button is pressed pump will start according to it s previous...

Page 10: ...s UP or DOWN arrow to scroll through your options Press START to make a selection The radio button square box is now filled in next to your selection Press DOWN arrow to scroll down to Done selection...

Page 11: ...ay time value from 1 255 seconds must be programmed An alarm delay value of 000 seconds disables FVS system If FVS alarm occurs pump will stop send an external signal if setup and screen will flash FV...

Page 12: ...d select no and press enter Turn on the pump press start If the TFD system detects the chemical the pump will stop after a two second confirmation period and the TFD Alarm screen will display If the T...

Page 13: ...angements to allow back flow If your desire is to simply extend tube life Typically tubing fails on outlet side pressure side of tube assembly in pump head Failure to install checkvalves in their prop...

Page 14: ...Head and Rotor Rotor can be removed by pulling straight out After cleaning process push Rotor back on shaft See drawing above for proper assembly IMPORTANT Rotor direction the word FRONT on Rotor mus...

Page 15: ...parts are being attacked and replace them with parts that have been manufactured using more suitable materials Manufacturer does not assume responsibility for damage to pump that has been caused by c...

Page 16: ...le directing tube into pump head At this point you may need to pull Tube Installation Tool to stretch tubing into position Let rotor spin a few rotations while pulling Installation tool so fitting can...

Page 17: ...able with single roller assembly rotor Tubing in this group are interchangeable with single roller assembly rotor Tygothane Stainless Steel extended mounting bracket kit pair Rubber feet 72000 380 900...

Page 18: ...with water only for pressure and performance Installers and operators of these devices must be well informed and aware of the precautions to be taken when injecting various chemicals especially those...

Reviews: