Operation
7.2 Faults - causes and rectification
40
Edition 09/2022
M3401-02en
• Flange surfaces of screwed connections not cleaned.
• Alignment and/or shaft misalignment values not set in accordance with the instructions.
• Coupled machines were not correctly connected to the foundation so that a shifting of
the machines leads to an impermissible displacement of the coupling parts.
• Coupled machines not earthed adequately.
• Coupling guard used is not suitable.
7.2.2.2.3
Maintenance-related causes
7.2 Faults - causes and rectification
• Stipulated maintenance intervals not adhered to.
• Spare parts that were used were not original spare parts from Flender.
• Flender spare parts that were used were old or damaged.
• Leak in the area of the coupling not detected so that chemically aggressive substances
damage the coupling.
• Indications of faults, such as noise or vibration, were not heeded.
• Stipulated tightening torques not adhered to.
• Alignment and/or shaft misalignment values not set in accordance with the instructions.
7.2.2.2.4
Specific installation-related and maintenance-related causes
7.2 Faults - causes and rectification
• Cam ring (50) not fitted.
• Fitted cam ring (50) excessively heated up when applying heat to the coupling parts.
7.2.3
Correcting faults
7.2 Faults - causes and rectification
7.2.3.1
Replacing wearing parts
7.2 Faults - causes and rectification
Cam rings (50) are subject to wear and this wear can result in torsional backlash.
Procedure
1. Check the wear on the cam ring (50) (see section Maximum permissible torsional back-
2. Replace the cam ring (50) where appropriate (see section Replacing wearing parts
7.2.3.2
Correcting the changed alignment
7.2 Faults - causes and rectification
A changed alignment of the coupling during operation often occurs when the coupled ma-
chines shift towards one another. A cause of this can be loose foundation bolts.
Procedure
1. Correct the cause for the change in alignment.
2. Check the wearing parts for wear and replace them as required.
Summary of Contents for N-BIPEX BNT
Page 1: ...BWN BWT BNT Assembly and operating instructions M3401 02en Edition 09 2022 N BIPEX ...
Page 6: ...Table of contents 6 Edition 09 2022 M3401 02en ...
Page 8: ...List of tables 8 Edition 09 2022 M3401 02en ...
Page 10: ...List of figures 10 Edition 09 2022 M3401 02en ...
Page 14: ...Introduction 1 4 Copyright 14 Edition 09 2022 M3401 02en ...
Page 36: ...Commissioning 36 Edition 09 2022 M3401 02en ...
Page 42: ...Operation 7 2 Faults causes and rectification 42 Edition 09 2022 M3401 02en ...
Page 46: ...Servicing 8 5 Removing coupling part 3 3 or 4 4 46 Edition 09 2022 M3401 02en ...
Page 48: ...Service and support 9 1 Contact 48 Edition 09 2022 M3401 02en ...
Page 50: ...Disposal 50 Edition 09 2022 M3401 02en ...
Page 54: ...Spare parts 11 2 Spare parts drawing and spare parts list 54 Edition 09 2022 M3401 02en ...
Page 64: ...Technical data Cam rings 64 Edition 09 2022 M3401 02en ...
Page 66: ...Declaration of Conformity UK Declaration of Conformity 66 Edition 09 2022 M3401 02en ...
Page 67: ......