Commissioning
6
In order to ensure safe commissioning, carry out various tests prior to commissioning.
Testing before commissioning
WARNING
Danger
Overload conditions can occur during the commissioning of the coupling. The coupling can
burst and metal parts can be flung out. There is a risk of fatal injury from flying fragments.
● Carry out the tests prior to commissioning.
● Do not touch the rotating coupling.
1. Check the tightening torques of the screws of the coupling in accordance with section
Tightening torques and widths A/F (Page 63).
2. Check the tightening torques of the foundation bolts of the coupled machines.
3. Check whether the enclosures (coupling guard, touch protection) have been installed and
that the function of the coupling has not been adversely affected by the enclosure. This
also applies to test runs and rotational direction checks.